Furnace 1st Floor
• Inducer Amps MNF/ - Test/1.0A
• Clean Flame Sensor Cleaned Flame Sensor
• Blower Motor Capacitor MNF/ - Test/
[email protected]
• Inspect Wiring All Wiring Is Good
• Inspect Burner Cleaned Burners To Be Free Of Obstruction
• Inspect Orifices For Blockage No Blockages
• Carbon Monoxide Test No Issues
• Inspect Chimney Chimney Is Venting Properly
• Inspect Pressure Switch Lines Cleared Pressure Switch Lines, All Good No Issues
• Test Sequence Of Operation Sequence Of Operations Is Good And In Order
• Inspect Heat Exchanger Clean Flame, But Water Leaking By The Bottom Where The Inducer Motor Is At
• Check Ignitor Ignitor Has Good Continuity
• Check/replace The Filter Replaced Filter
• Test Gas Shut Off No Issues
• Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Furnace 2nd Floor
• Inducer Amps MNF/ - Test/1.0A
• Clean Flame Sensor Cleaned Flame Sensor
• Blower Motor Capacitor MNF/ - Test/
[email protected]
• Inspect Wiring All Wiring Is Good
• Inspect Burner Cleaned Burners, They Are Free Of Obstruction
• Inspect Orifices For Blockage No Blockages
• Carbon Monoxide Test No Issues
• Inspect Chimney Chimney Is Venting Properly
• Inspect Pressure Switch Lines No Blockages, Free Of Obstruction
• Test Sequence Of Operation Sequence Of Operations Is Good And In Order
• Inspect Heat Exchanger Heat Exchanger Is Good. Little Water Damage Leak At The Bottom
• Check Ignitor Ignitor Has Good Continuity
• Check/replace The Filter Replaced Filter
• Test Gas Shut Off No Issues
• Test Thermostat For Proper Operation Thermostat Turns On Call No Issues