Are you looking for gas furnace maintenance in Winfield, IL ? Our heating and furnace service technicians have years of experience working on furnaces like yours in Winfield, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.
We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.
We provide gas furnace Maintenance Agreements in Winfield, IL
Furnace Report:
Furnace Report
• Inducer No Issues
• Clean Flame Sensor Cleaned Sensor Dirty
• Inspect Blower Motor No Issues
• Inspect Wiring No Issues
• Inspect Burner No Rust
• Inspect Orfices For Blockage Cleared All Ports
• Carbon Monoxide Test 0ppm Found
• Inspect Chimney No Issues
• Inspect Pressure Switch Lines No Issues
• Test Sequence Of Operation No Issues
• Inspect Heat Exchanger No Issues
• Check Ignitor No Issues
• Check/replace Filter Air Filter Looks Good
• Test Gas Shut Off No Issues
• Test Thermostat For Proper Operation No Issues
Lilita , S. Winfield, IL
01-18-2022
Upon Arrival Pre Clean Up Start-up Operations Are Good. The Interior Of The Furnace Was A Bit Dirty. Cleaned Up The Interior Of The Furnace, Flame Sensor, Burner Assembly & Motors Housing. Post-clean-up Start-up Operations Are Good. Motors Are Working Well Within Amp Rate. Air Filter Is Still Good.
Karen, S. Winfield, IL
11-02-2021
Furnace Report
• Inducer Amps MNF/ - Test/1.6A
• Clean Flame Sensor Cleaned Flame Sensor
• Blower Motor Capacitor MNF/ - Test/N/A Relay
• Inspect Wiring All Wiring Is Good
• Inspect Burner Cleaned Burners, They Are Free Of Obstruction
• Inspect Orifices For Blockage No Blockages
• Carbon Monoxide Test No Issues
• Inspect Chimney Chimney Is Venting Properly
• Inspect Pressure Switch Lines No Blockages, Free Of Obstruction
• Test Sequence Of Operation Sequence Of Operations Is Good And In Order
• Inspect Heat Exchanger No Issues, No Cracks Clean Flame
• Check Ignitor Ignitor Has Good Continuity
• Check/replace The Filter Filter Is Clean
• Test Gas Shut Off No Issues
• Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Bob , M. Winfield , IL
10-15-2022
Furnace Report:
Furnace Report
• Inducer No Issues
• Clean Flame Sensor Cleaned Sensor
• Inspect Blower Motor No Issues
• Inspect Wiring No Issues
• Inspect Burner No Rust
• Inspect Orfices For Blockage Cleared All Ports
• Carbon Monoxide Test 0ppm Found
• Inspect Chimney No Issues
• Inspect Pressure Switch Lines No Issues
• Test Sequence Of Operation No Issues
• Inspect Heat Exchanger No Issues
• Check Ignitor No Issues
• Check/replace Filter Air Filter Looks Good
• Test Gas Shut Off No Issues
• Test Thermostat For Proper Operation No Issues
Randy, M. Winfield , IL
01-06-2022
Found Pilot Not Staying Lit Tested Thermocouple At 24mv Recommended Replacing Gas Valve
John , P. Winfield, IL
01-06-2022
T Furnace Report:
Furnace Report
• Inducer Amps MNF/ - Test/0.5A
• Clean Flame Sensor Cleaned Flame Sensor
• Blower Motor Capacitor MNF/ - Test/
• Inspect Wiring All Wiring Looks Good
• Inspect Burner Cleaned Burners They Are Free Of Obstruction
• Inspect Orifices For Blockage No Blockages
• Carbon Monoxide Test No Issues
• Inspect Chimney Chimney Is Venting Properly
• Inspect Pressure Switch Lines No Blockages They Are Free Of Obstruction
• Test Sequence Of Operation Sequence Of Operations Is Good And In Order
• Inspect Heat Exchanger Clean Flame, No Cracks
• Check Ignitor Ignitor Has Good Continuity
• Check/replace The Filter Filter Is Clean
• Test Gas Shut Off No Issues
• Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Michael, L. Winfield, IL
10-15-2022
Upon Arrival. Furnace Sequence Of Operations Is All Working. Vent Motor Is Running At 1.9 Amps. Its Rated For 1.6
Robin K. , Y. Winfield , IL
09-20-2021
Upon Arrival Pre Clean Up Start Up Operations Are Good. The Interior Of The Furnace Was Really Dirty Due To Remodel Work In The House. Cleaned Up Interior Of Furnace, Flame Sensor, Burner Assembly & Motors Housing . Post Clean Up Start Up Operations Are Good . Motors Are Working Well Within Amp Rate . Check Up On Filter When More Remodel Work Is Being Done In The House .
Cyndee, F. Winfield, IL
10-29-2021
Due To The Age Of The Unit I Feel A New System Would Be A Better Fit. We Offer Some Great Financing Options
Annual Furnace Preventative Maintenance:
Furnace Report
Manufacturer Date 2006
• Inducer MNF/1.75 Test/1.7
• Clean Flame Sensor
• Inspect Blower Motor
• Inspect Wiring
• Inspect Burner
• Inspect Orfices For Blockage
• Carbon Monoxide Test
• Inspect Chimney
• Inspect Pressure Switch Lines
• Test Sequence Of Operation
• Inspect Heat Exchanger - Heavy Signs Rust
• Check Ignitor
• Check/replace Filter
• Check Drain
• Inspect Intake For Debris
• Test Gas Shut Off
• Test Thermostat For Proper Operation
• Blower Capacitor
Inducer Bearings Failing
Inducer Running High Amps
Jeff, I. Winfield , IL
09-21-2021
Annual Furnace Preventative Maintenance:
Furnace Report
Manufacturer Date 2006
• Inducer MNF/1.75 Test/1.7
• Clean Flame Sensor
• Inspect Blower Motor
• Inspect Wiring
• Inspect Burner
• Inspect Orfices For Blockage
• Carbon Monoxide Test
• Inspect Chimney
• Inspect Pressure Switch Lines
• Test Sequence Of Operation
• Inspect Heat Exchanger - Heavy Signs Rust
• Check Ignitor
• Check/replace Filter
• Check Drain
• Inspect Intake For Debris
• Test Gas Shut Off
• Test Thermostat For Proper Operation
• Blower Capacitor
Inducer Bearings Failing
Inducer Running High Amps
Jeff, I. Winfield , IL