Air Conditioning Maintenance

Air Conditioning Maintenance

Are you looking for Air Conditioning maintenance in Winfield, IL ? Our AC and Air Conditioning service technicians have years of experience working on Central AC Systems like yours in Winfield, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your Cooling System back up and operating.

We offer Central Air Conditioner maintenance and maintenance agreements to keep your AC system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency Air Conditioner today.

We provide Air Conditioning Maintenance in Winfield, IL

We provide Air Conditioning Maintenance Agreements in Winfield, IL

Get Your Quote Today

Upon Arrival. Outdoor AC Equipment Fan Motor Was A Bit High On Amps, After Clean Up The Amps Went Down. Furnace Motors Are Working Properly, Nice Blue Flame Indicating Proper Burn. FPM Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter ACPM Annual A/C Preventative Maintenance: Annual A/C Preventative Maintenance: Clean And Check Outdoor Condenser High Pressure - 154 Low Pressure - 59 Ambient Temp - 79 Delta T Reading -17 Contactor Resistance Reading -17.4 Low Voltage Wiring Check Capacitor Reading 40/5 Clean Out Electrical Compartment Refrigeration Line Check - Low Side Insulation Service Valve Cap Amp Draw On Compressor -8 Amp Draw On Condenser Fan -1.1 Check Filter/Replace Clean Drain Test Blower Motor
Martin , D. Winfield , IL
09-20-2021
Armstrong HVAC 4SCU13LE130P-5
AC Tune Up AC Clean AC Report Clean & Check
Lilita , S. Winfield, IL
06-12-2020
Upon Arrival We Met With Patricia Who Kindly Show Us The Furnace And The Outside Unit. We Commence The Maintenance On The Unit. Change The Filter That Patricia Provided. Everything Check Out Good And Is Working Properly At The Moment.
Patricia, C. Winfield, IL
07-17-2024
A/C Report Clean And Check Outdoor Condenser High Pressure - 300 Low Pressure - 115 Ambient Temp - 80 Delta T Reading -18 Contactor Resistance Reading - No Issues Low Voltage Wiring Check No Issues Capacitor Reading 45/5@44.83/4.94 Clean Out Electrical Compartment Cleaned Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap No Issues Amp Draw On Compressor -14.1@8.8 Amp Draw On Condenser Fan -1.5@.60 Lock Rotor Amps - 77@75 Check Filter/Replace Air Filter Looks Good Clean Drain No Issues Test Blower Motor No Issues
Cyndee, F. Winfield, IL
06-03-2022
Comfortmaker NAC036A
Clean And Inspection A/C A/C Report Clean And Check Outdoor Condenser High Pressure - 115 Low Pressure - 230 Delta T Reading 20 Contractor Resistance Reading 0 Low Voltage Wiring Check Capacitor Reading - 47/4.98 Clean Out Electrical Compartment Refrigeration Line Check - Low Side Insulation Service Valve Cap Amp Draw On Compressor - 7.49 Amp Draw On Condenser Fan .75 Check Filter/Replace Clean Drain Clean And Inspect Air Conditioner Clean Condenser Coil Check All Electrical Connections And Wiring Check High Side And Low Side Pressures Check Refrigerant Levels. Check Temperature Difference Replace Furnace Filter
Jake, L. Winfield, IL
06-12-2020
, Verified Sequence Of Operation Through Thermostat And Inspected Blower Department And Blower Was Clean But Air Filter Was Extremely Dirty And Took Out To Get Proper Refrigerant Levels As They Did Not Have Replacement (16x25x1). Tested Mechanical Components Of Ac Unit And Found Contactor Chattering And Higher End Of Specs For Resistance Levels. Please Reference Tune Up Form For Specifications. Homeowner Approved And Replaced And Tested. Refrigerant Levels Were Really Good And System Is Ready For Summer Season.
Luke , S. Winfield , IL
04-08-2024
A/C Report: A/C Report Clean And Check Outdoor Condenser High Pressure - 255 Low Pressure - 125 Ambient Temp - 76 Delta T Reading -19 Contactor Resistance Reading - No Issues Low Voltage Wiring Check No Issues Capacitor Reading 45/5@45/5 Clean Out Electrical Compartment Clean Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap In Place Amp Draw On Compressor -14.1@7.45 Amp Draw On Condenser Fan -1.4@.74 Lock Rotor Amps - 77@80.3 Check Filter/Replace Air Filter Looks Good Clean Drain Clear Test Blower Motor No Issues
Jeremiah , H. Winfield , IL
08-06-2022