Upon Arrival, Pre-clean-up Start-up Operations Are Good. Motors Are Working Well Within Amp Rate. The Flame Sensor Is A Bit Dirty, Switches Are Good. Cleaned Up Flame Sensor, Motors Housing, Burner Assembly, The Interior Of The Furnace. Current Filter Good & Humidifier In Good Operation. Humidifier Maintenance Provided
Humidifier Maintenance And Cleaning
Disassemble And Inspect Aprilaire Humidifier
-Clean Drain Assembly
-Clean Distribution Tray
-Clean Water Feed Tube
-Verify Water Flow, Clean Orifice
-Clean Or Replace Drain Tube As Needed
-Verify 24v Control Operation
-Replace Media Filter
Set Manual Controls @ 35% For Winter Opperaion.
Verify Automatic Control Set In WiFi Stat
Annual Furnace Preventative Maintenance:
Your Fall Preventative Maintenance Includes
- Clean Burner Assembly
- Clean Flame Sensor
- Inspect Heat Exchanger
- Check Igniter
- Test Safety Circuit
- Carbon Monoxide Test
- Check Sequence Operations
- Inspect Blower Motor And Cage
- Measure For Correct Air Flow
- Tighten Electrical Connections
- Measure Volts/amps On Motors
- Change Filter
James, K. Wheaton, IL
10-14-2021