Are you looking for gas furnace maintenance in Wheaton, IL ? Our heating and furnace service technicians have years of experience working on furnaces like yours in Wheaton, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace Maintenance Agreements in Wheaton, IL

Get Your Quote Today

Upon Arrival Pre Clean Up, Furnace Start-up Operations Are Good. Motors Amps Within Operation Rate. The Flame Sensor Was A Bit Dirty. Cleaned Up Motor Housing, The Interior Of The Furnace, Flame Sensor & Burner’s Assembly. The Current Filter Is Still Good, Recommended To Change It In About 3 Weeks. Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Judy , V. Wheaton , IL
10-20-2021
Furnace Report: Furnace Report • Inducer ( Needs To Be Replaced) • Clean Flame Sensor • Inspect Blower Motor • Inspect Wiring • Inspect Burner • Inspect Orfices For Blockage • Carbon Monoxide Test • Inspect Chimney • Inspect Pressure Switch Lines • Test Sequence Of Operation • Inspect Heat Exchanger • Check Ignitor • Check/replace Filter • Test Gas Shut Off • Test Thermostat For Proper Operation Humidifier Maintenance And Cleaning Disassemble And Inspect Aprilaire Humidifier -Clean Drain Assembly -Clean Distribution Tray -Clean Water Feed Tube -Verify Water Flow, Clean Orifice -Clean Or Replace Drain Tube As Needed -Verify 24v Control Operation -Replace Media Filter
Yannick , K. Wheaton, IL
12-06-2021
Upon Arrival, Called For Heat And Furnace Is Operating Good. Clean And Check On All Motors In Furnace. Furnace Seems To Have Taken Water Damage From Freezing AC Lines, Customer Stated One Our Techs Has Came Out To Their Home A Month Prior & Put Dye In Their System For Leak Check.
Julie, H. Wheaton, IL
09-20-2021
Furnace Report: Furnace Report • Inducer Amps MNF/ 1.45- Test/1.3 • Clean Flame Sensor Cleaned Sensor Dirty • Blower Motor Capacitor MNF/ 5- Test/4.8 • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orifices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace The Filter Air Filter Looks Good • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Sandy , J. Wheaton , IL
03-03-2022
Furnace Report • Inducer Amps MNF/2.35 - Test/ • Clean Flame Sensor- Yes • Blower Motor Capacitor MNF/5mfd - Test/4.9mfd • Inspect Wiring-yes • Inspect Burner-yes • Inspect Orifices For Blockage-yes • Carbon Monoxide Test-no • Inspect Chimney Yes • Inspect Pressure Switch Lines- Yes • Test Sequence Of Operation-yes • Inspect Heat Exchanger No • Check Ignitor Yes 49.9 Ohms • Check/replace The Filter- Yes • Test Gas Shut Off- Yes • Test Thermostat For Proper Operation- Yes Furnace Report • Inducer Amps MNF/1.0 - Test/1.03 • Clean Flame Sensor Yes • Blower Motor Capacitor MNF/5mfd - Test/4.7mfd • Inspect Wiring Yes • Inspect Burner Yes • Inspect Orifices For Blockage Yes • Carbon Monoxide Test No • Inspect Chimney Yes • Inspect Pressure Switch Lines Yes • Test Sequence Of Operation Yes • Inspect Heat Exchanger No • Check Ignitor Yes 82.57 Ohms • Check/replace The Filter Yes • Test Gas Shut Off Yes • Test Thermostat For Proper Operation Yes
Tom, L. Wheaton , IL
11-03-2022
Furnace Report: Furnace Report • Inducer Amps MNF/1.2 - Test/.89 • Clean Flame Sensor Cleaned Sensor • Blower Motor Capacitor MNF/5 - Test/4.9 • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orifices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation. No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues 51.4 Ohms .47 Amps • Check/replace The Filter Air Filter Looks Good • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues A/C Report Clean And Check Outdoor Condenser High Pressure - 220 Low Pressure - 105 Ambient Temp - 68 Delta T Reading -18 Contactor Resistance Reading - No Issues Low Voltage Wiring Check No Issues Capacitor Reading 35/5@35/4.8 Clean Out Electrical Compartment Cleaned Spider Webs Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap In Place Amp Draw On Compressor [email protected] Amp Draw On Condenser Fan [email protected] Lock Rotor Amps - [email protected] Recommended Hard Start Kit Check Filter/Replace Air Filter Looks Good Clean Drain No Leaks Test Blower Motor No Issues
Diane, R. Wheaton, IL
09-29-2022
Furnace Report: • Inducer Mmf .65 @ .25 • Clean Flame Sensor • Inspect Blower Motor Cleaned • Inspect Wiring Electrical Looks Good • Inspect Burner No Rust Or Bouncing Around • Inspect Orfices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney NA • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Faults • Inspect Heat Exchanger Looks Good • Check Ignitor Tested Ohms And Amps Good • Check/replace Filter Air Filter Was Just Replaced • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Cheryl , P. Wheaton, IL
12-09-2021