Are you looking for gas furnace maintenance in Warrenville, IL ? Our heating and furnace service technicians have years of experience working on furnaces like yours in Warrenville, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.
We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.
We provide gas furnace Maintenance Agreements in Warrenville, IL
Furnace Report:
Furnace Report 1st Floor
• Inducer .65 @.45
• Clean Flame Sensor Cleaned Sensor
• Inspect Blower Motor No Issues
• Inspect Wiring No Issues
• Inspect Burner No Rust
• Inspect Orfices For Blockage Cleared All Ports
• Carbon Monoxide Test 0ppm Found
• Inspect Chimney NA
• Inspect Pressure Switch Lines No Issues
• Test Sequence Of Operation No Issues
• Inspect Heat Exchanger No Issues
• Check Ignitor No Issues
• Check/replace Filter Replaced Air Filter
• Test Gas Shut Off No Issues
• Test Thermostat For Proper Operation No Issues
Humidifier Maintenance:
Humidifier Maintenance And Cleaning
Disassemble And Inspect Aprilaire Humidifier
-Clean Drain Assembly
-Clean Distribution Tray
-Clean Water Feed Tube
-Verify Water Flow, Clean Orifice
-Clean Or Replace Drain Tube As Needed
-Verify 24v Control Operation
-Replace Media Filter
Set Manual Controls @ 35% For Winter Opperaion.
Verify Automatic Control Set In WiFi Stat
Chris , S. warrenville, IL
12-20-2021
Furnace Report:
Furnace Report
• Inducer Amps MNF/.56 - Test/.48
• Clean Flame Sensor Cleaned Sensor Dirty
• Blower Motor Capacitor MNF/5 - Test/4.9
• Inspect Wiring No Issues
• Inspect Burner No Rust
• Inspect Orifices For Blockage Cleared All Ports
• Carbon Monoxide Test 0ppm Found
• Inspect Chimney No Issues
• Inspect Pressure Switch Lines No Issues
• Test Sequence Of Operation No Issues
• Inspect Heat Exchanger No Issues
• Check Ignitor No Issues
• Check/replace The Filter Air Filter Looks Good
• Test Gas Shut Off No Issues
• Test Thermostat For Proper Operation No Issues
Darlene, S. Warrenville, IL
02-25-2022
Upon Arrival, Outdoor Ac Fan Motor Was Running A Bit High Possibly Due To Dirty Condenser, After Clean Up Amps Went Down. Furnace Motors Are All In Good Working Rate & Cleaned Up Flame Sensor & Furnace Interior
FPM Annual Furnace Preventative Maintenance:
Your Fall Preventative Maintenance Includes
- Clean Burner Assembly
- Clean Flame Sensor
- Inspect Heat Exchanger
- Check Igniter
- Test Safety Circuit
- Carbon Monoxide Test
- Check Sequence Operations
- Inspect Blower Motor And Cage
- Measure For Correct Air Flow
- Tighten Electrical Connections
- Measure Volts/amps On Motors
- Change Filter
ACPM Annual A/C Preventative Maintenance:
Annual A/C Preventative Maintenance:
Clean And Check Outdoor Condenser
High Pressure -273/9
Low Pressure - 129/17
Ambient Temp - 70
Delta T Reading -19
Contactor Resistance Reading -19.5
Low Voltage Wiring Check
Capacitor Reading 40/5
Clean Out Electrical Compartment
Refrigeration Line Check - Low Side Insulation
Service Valve Cap
Amp Draw On Compressor -6 Amps
Amp Draw On Condenser Fan -.7
Check Filter/Replace
Clean Drain
Test Blower Motor
Katie , O. Warrenville, IL
09-21-2021
Upon Arrival Pre Clean Up, Furnace Start-up Operations Are Good. Motors Amps Within Operation Rate. The Furnace Air Filter Really Dirty, The Flame Sensor Was A Bit Dirty. Cleaned Up Motor Housing, The Interior Of The Furnace, Flame Sensor & Burner’s Assembly & Put In A New Furnace Air Filter (homeowner Provided). Post Clean Start-up Operations Good.
Annual Furnace Preventative Maintenance:
Your Fall Preventative Maintenance Includes
- Clean Burner Assembly
- Clean Flame Sensor
- Inspect Heat Exchanger
- Check Igniter
- Test Safety Circuit
- Carbon Monoxide Test
- Check Sequence Operations
- Inspect Blower Motor And Cage
- Measure For Correct Air Flow
- Tighten Electrical Connections
- Measure Volts/amps On Motors
- Change Filter
Maureen, G. Warrenville, IL