Furnace Report:
Furnace Report 1st Floor Start Up
• Inducer Amps MNF/ - Test/
• Clean Flame Sensor Clean
• Blower Motor Capacitor MNF/ - Test/
• Inspect Wiring No Issues
• Inspect Burner No Issues
• Inspect Orifices For Blockage No Issues
• Carbon Monoxide Test No Issues
• Inspect Chimney No Issues
• Inspect Pressure Switch Lines No Issues
• Test Sequence Of Operation No Issues
• Inspect Heat Exchanger No Issues
• Check Ignitor No Issues
• Check/replace The Filter Air Filter Clean
• Test Gas Shut Off No Issues
• Test Thermostat For Proper Operation No Issues
Furnace Report:
Furnace Report 1st Floor Dinning Room/kitchen
• Inducer Amps MNF/ - Test/
• Clean Flame Sensor Clean
• Blower Motor Capacitor MNF/ - Test/
• Inspect Wiring No Issues
• Inspect Burner No Issues
• Inspect Orifices For Blockage No Issues
• Carbon Monoxide Test No Issues
• Inspect Chimney No Issues
• Inspect Pressure Switch Lines No Issues
• Test Sequence Of Operation No Issues
• Inspect Heat Exchanger No Issues
• Check Ignitor No Issues
• Check/replace The Filter Clean
• Test Gas Shut Off. No Issues
• Test Thermostat For Proper Operation No Issues
Furnace Report:
Furnace Report Master
• Inducer Amps MNF/ - Test/
• Clean Flame Sensor Clean
• Blower Motor Capacitor MNF/ - Test/ No Issues
• Inspect Wiring No Issues
• Inspect Burner No Issues
• Inspect Orifices For Blockage No Issues
• Carbon Monoxide Test No
• Inspect Chimney No Issues
• Inspect Pressure Switch Lines No Issues
• Test Sequence Of Operation No Issues
• Inspect Heat Exchanger No Issues
• Check Ignitor No Issues
• Check/replace The Filter No Issues
• Test Gas Shut Off No Issues
• Test Thermostat For Proper Operation No Issues
Furnace Report:
Furnace Report Jack And Jill
• Inducer Amps MNF/ - Test/ No Issues
• Clean Flame Sensor No Issues
• Blower Motor Capacitor MNF/ - Test/
• Inspect Wiring No Issues
• Inspect Burner No Issues
• Inspect Orifices For Blockage No Issues
• Carbon Monoxide Test No Issues
• Inspect Chimney No Issues
• Inspect Pressure Switch Lines No Issues
• Test Sequence Of Operation No Issues
• Inspect Heat Exchanger No Issues
• Check Ignitor No Issues
• Check/replace The Filter Air Filter Looks Good
• Test Gas Shut Off No Issues
• Test Thermostat For Proper Operation No Issues
A/C Report:
A/C Report Dinning Room
Clean And Check Outdoor Condenser
High Pressure - 210
Low Pressure - 108
Ambient Temp - 56
Delta T Reading -18
Contactor Resistance Reading - No Issues
Low Voltage Wiring Check No W
Capacitor Reading 45/
[email protected]/5.06
Clean Out Electrical Compartment No Issues
Refrigeration Line Check - Low Side Insulation Well Insulated
Service Valve Cap No Issues
Amp Draw On Compressor -17.9@
Amp Draw On Condenser Fan -1.20@
Lock Rotor Amps - 112@
Check Filter/Replace Air Filter Looks Good
Clean Drain No Issues
Test Blower Motor No Issues
A/C Report Den
Clean And Check Outdoor Condenser
High Pressure - 210
Low Pressure - 105
Ambient Temp - 55
Delta T Reading -17
Contactor Resistance Reading - No Issues
Low Voltage Wiring Check No Issues
Capacitor Reading 45/
[email protected]/5.05
Clean Out Electrical Compartment Clean
Refrigeration Line Check - Low Side Insulation Well Insulated
Service Valve Cap No Issues
Amp Draw On Compressor
[email protected]
Amp Draw On Condenser Fan
[email protected]
Lock Rotor Amps -
[email protected]
Check Filter/Replace Air Filter Looks Good
Clean Drain No Issues
Test Blower Motor No Issues
A/C Report:
A/C Report Jack And Jill
Clean And Check Outdoor Condenser
High Pressure - 215
Low Pressure - 111
Ambient Temp - 56
Delta T Reading -18
Contactor Resistance Reading - No Issues
Low Voltage Wiring Check No Issues
Capacitor Reading 40/
[email protected]/5.02
Clean Out Electrical Compartment No Issues
Refrigeration Line Check - Low Side Insulation Well Insulated
Service Valve Cap No Issues
Amp Draw On Compressor
[email protected]
Amp Draw On Condenser Fan
[email protected]
Lock Rotor Amps -
[email protected]
Check Filter/Replace Air Filter Looks Good
Clean Drain No Issues
Test Blower Motor No Issues
A/C Report Master Bedroom
Clean And Check Outdoor Condenser
High Pressure - 208
Low Pressure - 110
Ambient Temp - 56
Delta T Reading -18
Contactor Resistance Reading - No Issues
Low Voltage Wiring Check No Issues
Capacitor Reading 40/
[email protected]/5.06
Clean Out Electrical Compartment No Issues
Refrigeration Line Check - Low Side Insulation Well Insulated
Service Valve Cap No Issues
Amp Draw On Compressor
[email protected]
Amp Draw On Condenser Fan
[email protected]
Lock Rotor Amps -
[email protected]
Check Filter/Replace No Issues
Clean Drain No Issues
Test Blower Motor No Issues
Joe , O. North Barrington , IL05-27-2022