Gas Furnace Maintenance

Gas Furnace Maintenance

Are you looking for gas furnace maintenance in Naperville, IL ? Our heating and furnace service technicians have years of experience working on furnaces like yours in Naperville, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace Maintenance Agreements in Naperville, IL

Get Your Quote Today

Furnace Report: Furnace Report • Inducer Amps MNF/1.0 - Test/.60 • Clean Flame Sensor • Inspect Blower Motor • Inspect Wiring • Inspect Burner • Inspect Orfices For Blockage • Carbon Monoxide Test • Inspect Chimney • Inspect Pressure Switch Lines • Test Sequence Of Operation • Inspect Heat Exchanger • Check Ignitor • Check/replace Filter • Test Gas Shut Off • Test Thermostat For Proper Operation Humidifier Maintenance And Cleaning Disassemble And Inspect Aprilaire Humidifier -Clean Drain Assembly -Clean Distribution Tray -Clean Water Feed Tube -Verify Water Flow, Clean Orifice -Clean Or Replace Drain Tube As Needed -Verify 24v Control Operation -Replace Media Filter
Phil , L. Naperville , IL
12-06-2021
Furnace Report: Furnace Report • Inducer Amps MNF/ - Test/3.4A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/[email protected] • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned And Cleared Burners • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney Is Venting Properly • Inspect Pressure Switch Lines Cleared Pressure Switch Lines • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger No Issues. Clean Flame No Cracks • Check Ignitor Ignitor Is All Good • Check/replace The Filter Filter Is Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Daniel , S. Naperville , IL
10-29-2022
Furnace Report: Furnace Report • Inducer Amps MNF/ - Test/ 0.6A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/ N/A Relay • Inspect Wiring Al Wiring Is Good • Inspect Burner Al Burners Are Clean And Free Of Obstruction • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney Is Venting Properly • Inspect Pressure Switch Lines No Blockages Free Of Obstruction • Test Sequence Of Operation Sequence Of Operations Is All Good • Inspect Heat Exchanger Heat Exchanger Is Good. Flame Is Clean And No Backfire • Check Ignitor Ignitor Is Good • Check/replace The Filter Filter Is Clean • Test Gas Shut Off Gas Shut My Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Janeth , A. Naperville, IL
09-23-2022

Jess, Q. Naperville , IL
03-03-2022
Furnace Report: Furnace Report Furnace Crawl Space • Inducer Amps MNF/ - Test/ 1.7A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/[email protected] • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned Burners They Are Free Of Obstruction • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney Is Venting Properly • Inspect Pressure Switch Lines Pressure Switch Lines Are Free Of Obstruction • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger • Check Ignitor Ignitor Has God Continuity • Check/replace The Filter Filter Needs To Be Cleaned • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues Furnace Report: Furnace Report • Inducer Amps MNF/ - Test/ N/A No Inducer • Clean Flame Sensor No Flame Sensor/ Pilot System • Blower Motor Capacitor MNF/ - Test/ N/A • Inspect Wiring Wiring Looks Good • Inspect Burner Cleaned Burners • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test Furnace Doesn’t Have A Inducer Motor. Carbon Monoxide Could Be Present In The Front Area Of Furnace • Inspect Chimney Chimney Is Present And Has Correct Pitch • Inspect Pressure Switch Lines No Pressure Switches • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger Heat Exchanger Is Very Rusty And Not In The Greatest Shape • Check Ignitor N/A Pilot • Check/replace The Filter Filter Is Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call Jo Issues
Cathy , B. Naperville , IL
10-15-2022
Furnace Operations Are Working Properly. The Vent Motor Is Running At 2.6 Amps, The Motor Is Rated For 1.15. The Blower Motor In Good Working Order. Cleaned Flame Sensor,interior Furnace & Motors Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter