is one of the leading providers of air conditioning repair and air conditioning service in Naperville, IL, offering timely solutions to problems related to your air conditioning system. Our HVAC technicians will come to your rescue when you want emergency AC service or repair, or just need a hand with your residential or commercial cooling problems.

You'll find we take our job seriously and highly value the trust that is placed in us. goes far beyond what others do by investing in the training and equipment necessary to protect your home or family in Naperville, IL. Whether you have a central AC system, Heat Pump or Ductless Mini Split we are here to help.

Get Your Quote Today

Circuit Board Was Fried At Condenser. Installed Circuit Board On Condenser Unit.
Aaron, A. Naperville, IL
07-30-2019
Found Ac Low On R22 Pressures At 160/45 Had To Add 2 Lbs Of R22 To Balance System Condenser Coil Really Dirty Recommended Preventative Maintenance Ac Now Cooling Properly.
Bradly , H. Naperville , IL
08-26-2022
Upon Arrival, I Met With Steven, Who Reported That The AC Was Not Working. I Checked The Thermostat And Set It To Cooling. I Then Located And Inspected The Furnace. Next, I Found The Condenser Outside, Checked The Pressures, And Discovered That The Unit Was Low On Refrigerant. Since The Installation Is Still Under Warranty, I Performed An Electronic Leak Detection And Found A Leak On The Suction Line Where It Connects To The Condenser. I Pumped Down The Unit And Repaired The Leak. After The Repair, I Conducted A Nitrogen Pressure Test, Which Held Successfully. I Then Put The Unit Under A Vacuum, Released The Charge, Added 4-1/2lbs Of R410a And Cycled The Unit. The AC Is Now Operating Properly.
Steve, T. Naperville, IL
05-31-2024
Air Conditioning Was Not Cooling On Arrival. Found Melted Wires At Capacitor. Rewired And Installed New 45/5 Mfd Capacitor On Air Conditioning Unit.
Jimmy, W. Naperville, IL
08-01-2019
Service: High Pressure - 225 Low Pressure - 70 Ambient Temp - 72 Delta T Reading -20 Contactor Resistance Reading - 8.0 (Marginal) Low Voltage Wiring Check Capacitor Reading (Replaced) Service Valve Cap Amp Draw On Compressor -14 (High) Amp Draw On Condenser Fan - 7.2
Arielle , L. Naperville , IL
10-07-2021