If your gas furnace in Lombard, IL is not working it is likely your furnace needs repair or service. At times the fix is simple, other times it is not. Our heating and furnace service technicians have years of experience working on furnaces like yours in Lombard, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.
Our furnace repair, furnace service or replacement pricing is very competitive. Our estimates are always firm with no hidden surprises. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.
We provide gas furnace service in Lombard, IL
We provide gas furnace repair in Lombard, IL
Upon Arrival, Homeowner Mentioned How Heat Went Out Yesterday And Has Had It Off. Turned Thermostat To Call For Heat To Verify Sequence Of Operation And Found Sequence Not Complete When Ignition Should Start. Tested Igniter And Found It To Read “OL”. Recommended Replacement To Further Test System And Homeowner Agreed. Replaced Igniter And Tested System And Checked Amp Draws And System Stayed On During Rest Of Visit.
Kris, B. Lombard, IL
04-10-2024
Upon Arrival, Homeowner Mentioned How Heat Went Out Yesterday And Has Had It Off. Turned Thermostat To Call For Heat To Verify Sequence Of Operation And Found Sequence Not Complete When Ignition Should Start. Tested Igniter And Found It To Read “OL”. Recommended Replacement To Further Test System And Homeowner Agreed. Replaced Igniter And Tested System And Checked Amp Draws And System Stayed On During Rest Of Visit.
Kris , B. Lombard, IL
04-10-2024
Blower Motor Was Intermittent. Tested All Wires. Checked Blower Capacitor. Tested Blower Amps. Connected C Wire On Nest Thermostat.
Brian, R. Lombard, IL
06-14-2019
Upon Arrival, Furnace Was Off On The Switch Near Furnace. Turned Unit On And Inducer Kicked On And Did Not Pass This Sequence. Disconnected Pressure Switch Hose And Found Blockage On Inducer Housing. Cleared Out House And Blockage And Re Tested System. Everything Turned On And Tested System And Everything Is Good To Go.
Linda, W. Lombard, IL
04-10-2024
Upon Arrival, Homeowner Mentioned OU High Pressure Switch Error. Upon Inspection Found Bunch Of Communication Errors And One OU Pressure High Open. Inspected And All Pressures Are Good To Manufacturing Specs And Everything Is Work Appropriately When System Restarted. Noticed Communication Error Kept Appearing. System Is Correctly Grounded But Did Not Have Shielded Wire For Communication Operations. Replaced Wire To Shield Wire And This Should Help With Communication Errors.
Javier, V. Lombard , IL
04-08-2024
Inducer Motor 2-Stage:
Inducer Motor
Pam , F. Lombard , IL
01-20-2022
Upon Arrival Tried To Turn The Thermostat To Heat Mode. The Thermostat Has No Setting For Heat. Upon Further Inspection, I Discovered The Heat Mode Was Shut Off On The Installer Settings. I Readded The Furnace To The Thermostat.
Kevin , S. Lombard , IL
10-20-2021
Diagnosed Severe Rust On Collector Box And Roll Out Flame On Burner Cracked Heat Exchanger
Susan, B. Lombard, IL
04-22-2019