Upon Arrival, Furnace Operations Are Good, Both Motors Are In A Good Working Amp Range. Cleaned Up The Interior Of The Furnace, Flame Sensor, Motors & Burner Assembly. Also Changed The Special Filter.
Annual Furnace Preventative Maintenance:
Your Fall Preventative Maintenance Includes
- Clean Burner Assembly
- Clean Flame Sensor
- Inspect Heat Exchanger
- Check Igniter
- Test Safety Circuit
- Carbon Monoxide Test
- Check Sequence Operations
- Inspect Blower Motor And Cage
- Measure For Correct Airflow
- Tighten Electrical Connections
- Measure Volts/amps On Motors
- Change Filter
Mid-Season Filter Change:
1 Mid Season Filter Change
Inspect Belts For Tension, Alignment, And Condition
Include 4 Standard Filters
Amanda , B. La Grange , IL
10-01-2021
Furnace Report
• Inducer Amps MNF/ - Test/ 1.5A
• Clean Flame Sensor Cleaned Flame Sensor
• Blower Motor Capacitor MNF/ - Test/10mfd@10.1mfd
• Inspect Wiring All Wiring Is Good
• Inspect Burner Cleaned And Cleared Burners Burners
• Inspect Orifices For Blockage No Blockages
• Carbon Monoxide Test No Issues
• Inspect Chimney Chimney Is Venting Properly
• Inspect Pressure Switch Lines Cleared Pressure Switch Lines
• Test Sequence Of Operation Sequence Of Operation Good And In Order
• Inspect Heat Exchanger No Issues Clean Flame
• Check Ignitor Ignitor Is Good
• Check/replace The Filter Replaced Filter
• Test Gas Shut Off No Issues
• Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Amanda , B. La Grange , IL
10-22-2022