Gas Furnace Maintenance

Gas Furnace Maintenance

Are you looking for gas furnace maintenance in Glendale Heights, IL ? Our heating and furnace service technicians have years of experience working on furnaces like yours in Glendale Heights, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace Maintenance Agreements in Glendale Heights, IL

Get Your Quote Today

Furnace Report: • Inducer Mmf/1.05 @ 1.03 • Clean Flame Sensor Sensor Is Clean • Inspect Blower Motor Looks Good • Inspect Wiring No Issues • Inspect Burner Burners Are Looking Good No Rust • Inspect Orfices For Blockage No Issues • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines All Clear • Test Sequence Of Operation No Issues • Inspect Heat Exchanger Flames Look Good No Bouncing Around • Check Ignitor Spark Ignition No Issues • Check/replace Filter Filter Is Clean • Test Gas Shut Off Shut Off Is Working Properly • Test Thermostat For Proper Operation No Issues Customer Mentioned That The Furnace Blower Kicks On Right Away When Flames Come On Timing Seems To Be Fine No Issues
Debi , K. Glendale Heights , IL
12-09-2021
Furnace Report: Furnace Report • Inducer No Issues • Clean Flame Sensor Cleaned Sensor • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orfices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Air Filter Looks Good • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Rich , G. Glendale Heights , IL
01-06-2022
Furnace Report: Furnace Report • Inducer Amps MNF/ - Test/ 0.5A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/ [email protected] • Inspect Wiring ALL WIRING IS GOOD • Inspect Burner CLEANED AND CLEARED BURNERS • Inspect Orifices For Blockage NO BLOCKAGES • Carbon Monoxide Test NO ISSUES • Inspect Chimney CHIMNEY IS VENTING PROPERLY • Inspect Pressure Switch Lines NO BLOCKAGES • Test Sequence Of Operation SEQUENCE OF OPERATIONS IS GOOD AND IN ORDER • Inspect Heat Exchanger HEAT EXCHANGER IS NOT CRAXKED BUT ITS OLD • Check Ignitor IGNITOR IS ALL GOOD • Check/replace The Filter FILTER IS CLEAN • Test Gas Shut Off Gas Shut Off Is Good • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Nicolas , L. Glendale Heights , IL
10-22-2022
Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Tim, G. Glendale Heights , IL
09-17-2021
Furnace Report: • Inducer Mmf/1.05 @ 1.03 • Clean Flame Sensor Sensor Is Clean • Inspect Blower Motor Looks Good • Inspect Wiring No Issues • Inspect Burner Burners Are Looking Good No Rust • Inspect Orfices For Blockage No Issues • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines All Clear • Test Sequence Of Operation No Issues • Inspect Heat Exchanger Flames Look Good No Bouncing Around • Check Ignitor Spark Ignition No Issues • Check/replace Filter Filter Is Clean • Test Gas Shut Off Shut Off Is Working Properly • Test Thermostat For Proper Operation No Issues Customer Mentioned That The Furnace Blower Kicks On Right Away When Flames Come On Timing Seems To Be Fine No Issues
Debi , K. Glendale Heights , IL
12-09-2021
Upon Arrival, Pre-clean-up Start-up Operations Are Good. Motors Are Within The Working Amp Rate. The Interior Of The Furnace Really Dusty, The Motor Housings Were Pretty Dusty. The Switches Are Good. Cleaned Up Furnace Interior, Flame Sensor, The Interior Of The Furnace, Burner Assembly, Motor Housings. Manufactured In March 2004. Also Patched Up Humidifier Hole In The Ductwork
Tom, C. Glendale Heights, IL
10-29-2021
A Small Gas Leak Coming From The Water Heater Union. Added Leak Lock To The Small Leak. No More Bubbles Coming From The Union. Check The Rest Of The Gas Piping. Didn’t Find Any Other Leak. The Customer Would Like An Estimate To The Re-pipe The Gas Pipe While The Furnace Gets Installed.
John, E. Glendale Heights , IL
10-04-2021