Furnace Service and Repair

Furnace Service and Repair

If your gas furnace in Glendale Heights, IL is not working it is likely your furnace needs repair or service. At times the fix is simple, other times it is not. Our heating and furnace service technicians have years of experience working on furnaces like yours in Glendale Heights, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

Our furnace repair, furnace service or replacement pricing is very competitive. Our estimates are always firm with no hidden surprises. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace service in Glendale Heights, IL

We provide gas furnace repair in Glendale Heights, IL

Get Your Quote Today

Furnace Report: • Inducer Amps Mmf/.76- Test .54 • Clean Flame Sensor Cleaned Sensor And Tested At 4.5 • Inspect Blower Motor Yes It’s Clean • Inspect Wiring Yes No Issues • Inspect Burner Clean No Issues • Inspect Orfices For Blockage No Spiders • Carbon Monoxide Test None Found • Inspect Chimney Yes No Issues • Inspect Pressure Switch Lines Yes No Issues • Test Sequence Of Operation System Fired No Issues • Inspect Heat Exchanger Yes No Rust • Check Ignitor Ohms And Amps Are Good • Check/replace Filter Filter Blocked Replaced Air Filter 14x25x1 • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Noel , C. Glendale Heights , IL
12-09-2021
"No Heat" On Arrival. Diagnosed Cracked Heat Exchanger
Mannuel, H. Glendale Heights, IL
04-26-2019
Furnace Giving A 3 Flash Code On Startup I Removed The Chimney To Verify Not Blocked, I Checked Continuity On The Pressure Switch. Discovered Inducer Not Pulling Pressure Switch In.
Jose , T. Glendale Heights , IL
10-21-2021
Upon Arrival, Talked About Homeowner About Metal Drip Noise. Verified Sequence Of Operation Through Thermostat And Found Everything Working Appropriately. Tested Induced And Blower Motor And Everything Is Between Manufacturing Specs. Drip Noise Is From Heat Exchanger Heating Up And Expanding And Cooling Down It Starts Making Noise. After It Cools Down. Noise Goes Away. Humidifier Is Operating Appropriately Also.
Debi , K. Glendale Heights , IL
04-10-2024