Are you looking for gas furnace maintenance in Glen Ellyn, IL ? Our heating and furnace service technicians have years of experience working on furnaces like yours in Glen Ellyn, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace Maintenance Agreements in Glen Ellyn, IL

Get Your Quote Today

Upon Arrival. Furnace Operations Are Good. Cleaned Up Motor Housing,burner Assembly, Interior Of The Furnace & Flame Sensor. Current Filter Still Good. Offered Humidifier Maintenance & Homeowner Declined.
Charles , B. Glen Ellyn, IL
10-08-2021
Furnace Report: Furnace Report • Inducer Amps MNF/0.65 - Test/0.35 • Clean Flame Sensor-yes • Blower Motor Capacitor MNF/ - Test/N/A • Inspect Wiring-yes • Inspect Burner-yes • Inspect Orifices For Blockage-yes • Carbon Monoxide Test-no • Inspect Chimney-yes • Inspect Pressure Switch Lines-yes • Test Sequence Of Operation-yes • Inspect Heat Exchanger-yes • Check Ignitor-yes 54.20 Ohms • Check/replace The Filter-yes • Test Gas Shut Off-yes • Test Thermostat For Proper Operation-yes
Bill , M. Glen Ellyn , IL
11-03-2022
Furnace Report: Furnace Report • Inducer No Issues • Clean Flame Sensor Cleaned Sensor • Inspect Blower Motor. No Issues • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orfices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Air Filter Looks Good • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Kathy , M. Glen Ellyn, IL
01-25-2022
Urnace Report: Boiler Report • Inducer NA • Clean Flame Sensor • Inspect Blower Motor NA • Inspect Wiring. No Issues • Inspect Burner No Issues • Inspect Orfices For Blockage NA • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines NA • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor Spark • Check/replace Filter NA • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Steven , C. Glen Ellyn, IL
02-01-2022
Completed Furnace Clean And Check. Upon Arrival, Verified Sequence Of Operation Through Thermostat And Found Everything To Be Between Manufacturing Specs And Output Of Unit Was Up To Specs. Please Reference Tune Up Form For Details On Inspection. Completed Humidifier Maintenance And Water Heater Maintenance During Visit. We Also Renewed Agreement During Visit.
Martin, F. Glen Ellyn, IL
04-10-2024
Upstairs Furnace - Vent Motor Running In Amp Range. Blower Motor In Good Amp Rate Range. Humidifier Wire Was Lose Causing No Connection & Filter Housing Was Loose Causing Leak, Humidifier In Good Working Order. Downstairs Furnace - Motors Are In Good Amp Operations . Humidifier Maintenance: Humidifier Maintenance And Cleaning Disassemble And Inspect Aprilaire Humidifier -Clean Drain Assembly -Clean Distribution Tray -Clean Water Feed Tube -Verify Water Flow, Clean Orifice -Clean Or Replace Drain Tube As Needed -Verify 24v Control Operation -Replace Media Filter Set Manual Controls @ 35% For Winter Opperaion. Verify Automatic Control Set In WiFi Stat
Jeff , P. Glen Ellyn, IL
09-24-2021
Furnace Report • Inducer Amps MNF/ - Test/ 0.3A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/ N/A Relay • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned And Cleared Burners • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney/exhaust Is Venting Properly • Inspect Pressure Switch Lines Cleared Pressure Switch Lines • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger No Issues. Clean Flame • Check Ignitor Ignitor Is All Good • Check/replace The Filter Replaced Filter 10-31-22 • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Lloyd , B. Glen Ellyn , IL
11-03-2022
Furnace Report • Inducer Amps MNF/ - Test/ 2.7A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/ 20MFD@19.6MFD • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned Burners They Are Free Of Obstruction • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney Is Venting Properly • Inspect Pressure Switch Lines Pressure Switch Lines Are Free Of Obstruction • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger Heat Exchanger Has No Cracks And Throws Clean Flame • Check Ignitor Ignitor Has Good Continuity • Check/replace The Filter Filter Is Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Leslie , O. Glen Ellyn , IL
10-15-2022