Air Conditioning Service, Repair and Installation
is one of the leading providers of air conditioning repair and air conditioning service in Glen Ellyn, IL, offering timely solutions to problems related to your air conditioning system. Our HVAC technicians will come to your rescue when you want emergency AC service or repair, or just need a hand with your residential or commercial cooling problems.
You'll find we take our job seriously and highly value the trust that is placed in us. goes far beyond what others do by investing in the training and equipment necessary to protect your home or family in Glen Ellyn, IL.
Whether you have a central AC system, Heat Pump or Ductless Mini Split we are here to help.
TRPCRG Residential Diagnosis Fee:
Residential Service & Diagnosis
Includes 1 Hour Of Standard Diagnosis On One HVAC System.
Each Additional System Diagnosis Will Have An Additional Fee.
Mickey , G. Glen Ellyn , IL
09-02-2021
Upon Arrival, I Met With Diane, Who Reported That The AC Was Not Cooling. Diane Set The Thermostat To Cooling, And I Proceeded To Inspect The Furnace. I Then Located The Condenser Outside And Checked The Pressures, Finding That The Unit Required A Top-off With R410a Refrigerant. There Were No Signs Of Major Leaks.
After Obtaining Verbal Approval From Diane, I Topped Off The Unit With 2 Lbs Of R410a. I Also Offered Diane Our Service Agreement Plan, And She Decided To Wait Until The Fall To Sign Up.
The Unit Is Currently Operating Properly.
Diane, N. Glen Ellyn, IL
05-31-2024
R22 / 90048 1 LB Refrigerant Chlorodifluoromethane:
Furnish And Install 1 LB R-22 Refrigerant.
HVAC - Residential Service
4050-12 / 90210 Easy UV Dye Direct INJ:
Easy Seal Leak Stop W/UV Dye Up To 5 Ton
Ultraviolet Dye Detects Larger Leaks
Perfect For Split Systems, Heat Pumps, Micro Channel Coils, Packaged Units And Mini-splits
Permanently Seals Even Larger Leaks
Rapid Fusion Technology For A Stronger Bond
Works With All Refrigerants
Treats Larger Systems
No Need To Pump Down The System
Proven Not To Plug TXVs, Cap Tubes Or Pistons
TRPCRG (1) Residential Diagnosis Fee (1):
Residential Service & Diagnosis
Includes 1 Hour Of Standard Diagnosis On One HVAC System.
Each Additional System Diagnosis Will Have An Additional Fee.
Joan , S. Glen Ellyn , IL
09-20-2021
Upon Arrival, I Met With Charlie And He Stated That The Furnace Was Not Blowing Any Air. I Set The Thermostat To Cooling And Located The Furnace. I Heard The Condenser Turn On, But The Blower Motor Did Not Activate. I Checked For 120V Power Coming To The Unit, But Did Not Find 120V At The Cooling Terminal For The Fan On The Circuit Board. I Verified There Was A Call For The Fan And Then Removed The Circuit Board. Upon Inspection, I Found Watermarks Behind The Board. Additionally, I Observed Three Different Stickers On The Furnace, Each Indicating That The Circuit Board Had Been Replaced Previously.
I Then Decided To Inspect The Evaporator Coil. It Was Extremely Dirty And In Need Of Cleaning. I Determined That When The Blower Activates, It Picks Up Water, Causing Damage To The Circuit Board. Furthermore, I Noticed That The Unit Was Using A 1-inch Filter Rated FPR 4-5 (equivalent To MERV 6), Which Is Insufficient For The Unit And Allows Debris To Quickly Dirty The Coil.
After Identifying The Root Cause Of The Water Damage To The Control Board, I Discussed The Findings With Charlie And Advised Him Of Various Options. Charlie Expressed Interest In Speaking With A Service Advisor About The Possibilities Of Replacing Both The Furnace And The Condenser.
Charlie, J. Glen Ellyn, IL
05-31-2024
Upon Arrival, Met Sherri And She Informed Me That The AC Was Not Functioning. After Inspecting The Thermostat, Which Indicated A Call For Cooling, I Proceeded To Check The Furnace To Ensure The Blower Was Operating Correctly And The Filter Was Clean. Upon Examination Of The Condenser Outside, I Discovered It Was Switched Off At The Disconnect. Before Reactivating It, I Inspected The Contactor And Dual Capacitor, Noting That It Was Not Within The Manufacturer’s Specifications. After Obtaining Approval From The Homeowners, I Replaced The Faulty Capacitor And Restarted The Unit. I Then Verified The Pressures And Supply Temperature To Ensure Optimal Operation. Additionally, The Homeowners Opted To Enroll In Our Maintenance Agreement Plan Starting This Fall.
Charlie, J. Glen Ellyn, IL
05-31-2024
Air Conditioner Was Not Cooling Properly On Second Floor. Found Unit Completely Empty On Refrigerant. Put 350 PSI Of Nitrogen In System With Valves Closed Outside.
Daniel, F. Glen Ellyn, IL
08-01-2019
Trane 2TTR4018A1000AService/Diagnostic (after Hours)
Trane Air Handler
No Cooling Upon Arrival
Failed Thermostat
Severely Clogged Air Filter - Causing Air Flow Restriction
Iced Over AC Coil
Repair
Thawed AC Coil Of Ice
Changed Clogged AIr Filter
Voltage Testing
Checked CFM Air Flow
New Honeywell Thermostat - Digital & Illuminated
Low Voltage Connection
Tutor Customer On How To Use.
Pat, H. Glen Ellyn, IL06-12-2020