Air Conditioning Service, Repair and Installation
is one of the leading providers of air conditioning repair and air conditioning service in Glen Ellyn, IL, offering timely solutions to problems related to your air conditioning system. Our HVAC technicians will come to your rescue when you want emergency AC service or repair, or just need a hand with your residential or commercial cooling problems.
You'll find we take our job seriously and highly value the trust that is placed in us. goes far beyond what others do by investing in the training and equipment necessary to protect your home or family in Glen Ellyn, IL.
Whether you have a central AC system, Heat Pump or Ductless Mini Split we are here to help.
R22 / 90048 1 LB Refrigerant Chlorodifluoromethane:
Furnish And Install 1 LB R-22 Refrigerant.
HVAC - Residential Service
4050-12 / 90210 Easy UV Dye Direct INJ:
Easy Seal Leak Stop W/UV Dye Up To 5 Ton
Ultraviolet Dye Detects Larger Leaks
Perfect For Split Systems, Heat Pumps, Micro Channel Coils, Packaged Units And Mini-splits
Permanently Seals Even Larger Leaks
Rapid Fusion Technology For A Stronger Bond
Works With All Refrigerants
Treats Larger Systems
No Need To Pump Down The System
Proven Not To Plug TXVs, Cap Tubes Or Pistons
TRPCRG (1) Residential Diagnosis Fee (1):
Residential Service & Diagnosis
Includes 1 Hour Of Standard Diagnosis On One HVAC System.
Each Additional System Diagnosis Will Have An Additional Fee.
Joan , S. Glen Ellyn , IL
09-20-2021
Annual Cleaning And Inspection Of Air Conditioner
Bob, C. Glen Ellyn, IL
04-24-2019
Upon Arrival, I Met With Jeff, Who Reported That The Second-floor AC Was Icing Up On The Line Set And Evaporator Coil. He Also Mentioned That The First-floor Condenser Had Ice On The Line Set. I Set Both Thermostats To Cooling And Checked The Pressures On Both Units, Finding Both To Be Low On Refrigerant—though Not Enough To Indicate A Significant Leak. The Slight Loss Could Be Attributed To The Small Release Of Gas When Attaching And Removing The Gauges.
I Recommended That Jeff Join Our Maintenance Plan, Which He Accepted. During The AC Maintenance, I Found That Both Condensers Had Contactors Showing Signs Of Wear And Tear. I Topped Off Both Units With 1.5 Lbs Of R410a Refrigerant Each.
After Completing The Maintenance On The Condensers, I Inspected The Blower Motors On Both Units. Both Motors Had Capacitors That Were Not Within Manufacturer Specifications.
At The End Of The Maintenance, I Spoke With Jeff’s Wife, Joie, And Explained All My Findings. I Sent An Estimate To Jeff Via Email. Currently, Both Units Are Operating.
Jeff, S. Glen Ellyn, IL
05-31-2024
A/C Unit Was Not Cooling On Arrival. Found Capacitor Failure At Outdoor Condenser. Installed New 55/5 Mfd Dual Run Capacitor.
Greg, M. Glen Ellyn, IL
07-30-2019
Annual Cleaning And Inspection Of Air Conditioner
Ed, O. Glen Ellyn, IL
06-14-2019
American Standard HVAC 4TTB3036*No AC - Found 2 Wire At Condenser Was Exposed And Resting Up Against Refrigerant Line. Breaker Tripped. Replaced About A 2’ Of Wire. Reset Breaker. Refrigerant Pressures Within Normal Charge Range With A 14° Sub Cooling. Coil Clean. Filter Ok. System Cooling Normally At This Time.
Meg, M. Glen Ellyn, IL09-05-2024
Upon Arrival, Met Sherri And She Informed Me That The AC Was Not Functioning. After Inspecting The Thermostat, Which Indicated A Call For Cooling, I Proceeded To Check The Furnace To Ensure The Blower Was Operating Correctly And The Filter Was Clean. Upon Examination Of The Condenser Outside, I Discovered It Was Switched Off At The Disconnect. Before Reactivating It, I Inspected The Contactor And Dual Capacitor, Noting That It Was Not Within The Manufacturer’s Specifications. After Obtaining Approval From The Homeowners, I Replaced The Faulty Capacitor And Restarted The Unit. I Then Verified The Pressures And Supply Temperature To Ensure Optimal Operation. Additionally, The Homeowners Opted To Enroll In Our Maintenance Agreement Plan Starting This Fall.
Charlie, J. Glen Ellyn, IL
05-31-2024