Are you looking for gas furnace maintenance in Downers Grove, IL ? Our heating and furnace service technicians have years of experience working on furnaces like yours in Downers Grove, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace Maintenance Agreements in Downers Grove, IL

Get Your Quote Today

Furnace Report • Inducer Amps MNF/1.0 - Test/ .70 • Clean Flame Sensor Yes • Blower Motor Capacitor MNF/ - Test/ N/A • Inspect Wiring Yes • Inspect Burner Yes • Inspect Orifices For Blockage Yes • Carbon Monoxide Test Yes • Inspect Chimney Yes • Inspect Pressure Switch Lines Yes • Test Sequence Of Operation Yes • Inspect Heat Exchanger Yes • Check Ignitor 50.8 Ohmns • Check/replace The Filter Yes And Replaced • Test Gas Shut Off Yes • Test Thermostat For Proper Operation Yes
Arielle , B. Downers Grove , IL
10-28-2022
Furnace Report: Furnace Report 2nd Floor • Inducer [email protected] • Clean Flame Sensor Cleaned Sensor • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orfices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney NA • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Replaced Air Filter AA413 • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues Furnace Report: Furnace Report 2nd Floor • Inducer 2.35@ 2.1 • Clean Flame Sensor Cleaned Sensor • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orfices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney NA • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Replaced Air Filter AA413 • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Chad, A. Downers Grove, IL
12-20-2021

Phil , H. Downers Grove , IL
01-13-2023
Furnace Report • Inducer Amps MNF/ - Test/0.5A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/ [email protected] • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned And Cleared Burners • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney/exhaust Venting Properly • Inspect Pressure Switch Lines Cleared Pressure Switch Lines • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger Heat Exchanger Is Good But Flames Are Shooting Out A Bit Messy • Check Ignitor Ignitor Is All Good • Check/replace The Filter Recommend Replacing Filter • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Abby , W. Downers Grove , IL
10-22-2022
FReport Furnace Report: Furnace Report 1st Floor • Inducer 1.8 MNF / Test 1.89 • Clean Flame Sensor • Inspect Blower Motor • Inspect Wiring • Inspect Burner • Inspect Orfices For Blockage • Carbon Monoxide Test • Inspect Chimney • Inspect Pressure Switch Lines • Test Sequence Of Operation • Inspect Heat Exchanger • Check Ignitor • Check/replace Filter • Test Gas Shut Off • Test Thermostat For Proper Operation FReport Furnace Report: Furnace Report 2nd Floor • Inducer 1.8 MNF / Test 1.75 • Clean Flame Sensor • Inspect Blower Motor • Inspect Wiring • Inspect Burner • Inspect Orfices For Blockage • Carbon Monoxide Test • Inspect Chimney • Inspect Pressure Switch Lines • Test Sequence Of Operation • Inspect Heat Exchanger • Check Ignitor • Check/replace Filter • Test Gas Shut Off • Test Thermostat For Proper Operation
Jim , J. Downers Grove , IL
09-29-2021
Furnace Report • Inducer Amps MNF/ - Test/ 0.4A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/N/A Relay • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned And Cleared Burners • Inspect Orifices For Blockage. I Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney/exhaust Is Venting Properly • Inspect Pressure Switch Lines Cleared Pressure Switch Lines • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger • Check Ignitor • Check/replace The Filter Replaced Filter • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Rusty , R. Downers Grove , IL
10-22-2022