Are you looking for gas furnace maintenance in Carol Stream, IL ? Our heating and furnace service technicians have years of experience working on furnaces like yours in Carol Stream, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace Maintenance Agreements in Carol Stream, IL

Get Your Quote Today

Upon Arrival, Furnace Operations Are Good. Motors Working Within Operating Amp Rate. Cleaned Up Motor Housing, Burner Assembly, Flame Sensor & Interior Of The Furnace. Also Offered Humidifier Maintenance & Homeowner Accepted. The Humidifier In Good Operations Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Airflow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter Humidifier Maintenance And Cleaning Disassemble And Inspect Aprilaire Humidifier -Clean Drain Assembly -Clean Distribution Tray -Clean Water Feed Tube -Verify Water Flow, Clean Orifice -Clean Or Replace Drain Tube As Needed -Verify 24v Control Operation -Replace Media Filter Set Manual Controls @ 35% For Winter Opperaion. Verify Automatic Control Set In WiFi Stat
Scott, P. Carol Stream, IL
10-08-2021
Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Inducer Amp Draw - 1.4 - Change Filter Inducer Motor Showing Signs Of Failure Recommend Replacement
Paulette , N. Carol Stream , IL
09-21-2021
Furnace Report: • Inducer Mmf .65 @ .35 • Clean Flame Sensor Sensor Is Cleaned • Inspect Blower Motor Blower Looks Good • Inspect Wiring No Issues • Inspect Burner Burners Look Good No Rust • Inspect Orfices For Blockage Cleared All Ports For Inducer Motor • Carbon Monoxide Test 0ppm Found • Inspect Chimney NA • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor Checked Ohms And Amps No Issues • Check/replace Filter Air Filter Looks Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues But Recommended Ecobee For Better Heat Distribution
Vince , P. Carol Stream , IL
12-09-2021
1.00 $85.00 $85.00 Cash HVAC - Residential Maintenance FReport Furnace Report: Furnace Report • Inducer Kinda Whiny 3.5 @ 2.9 • Clean Flame Sensor Cleaned Sensor • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orfices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Air Filter Looks Good • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Chuck, A. Carol Stream, IL
01-06-2022
Furnace Report: Furnace Report • Inducer No Issues • Clean Flame Sensor Cleaned Sensor Dirty • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orfices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Replaced Air Filter • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Jim& Joy, D. Carol Stream, IL
01-27-2022
Furnace Report: Furnace Report • Inducer .95 @ .84 • Clean Flame Sensor Cleaned Sensor • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orfices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney NA • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Replaced Air Filter Very Dirty • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues