Are you looking for gas furnace maintenance in Bloomingdale, IL ? Our heating and furnace service technicians have years of experience working on furnaces like yours in Bloomingdale, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.
We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.
We provide gas furnace Maintenance Agreements in Bloomingdale, IL
Furnace Report
• Inducer Amps MNF/.40 - Test/.42
• Clean Flame Sensor-yes
• Blower Motor Capacitor MNF/20 - Test/19.5
• Inspect Wiring-yes
• Inspect Burner-yes
• Inspect Orifices For Blockage-yes
• Carbon Monoxide Test-no
• Inspect Chimney-no
• Inspect Pressure Switch Lines-yes
• Test Sequence Of Operation-yrs
• Inspect Heat Exchanger-no
• Check Ignitor-yes 53.2 Ohms
• Check/replace The Filter-yes Did Not Replace
• Test Gas Shut Off-yes
• Test Thermostat For Proper Operation- Yes
Jean , S. Bloomingdale, IL
11-03-2022
Furnace Report
• Inducer Amps MNF/1.0 - Test/.90
• Clean Flame Sensor
• Inspect Blower Motor
• Inspect Wiring
• Inspect Burner
• Inspect Orfices For Blockage
• Carbon Monoxide Test
• Inspect Chimney
• Inspect Pressure Switch Lines
• Test Sequence Of Operation
• Inspect Heat Exchanger
• Check Ignitor (Recently Replaced)
• Check/replace Filter
• Test Gas Shut Off
• Test Thermostat For Proper Operation
Mike , M. Bloomingdale, IL
12-03-2021
Furnace Report
• Inducer Amps MNF/1.1 - .35
• Clean Flame Sensor
• Inspect Blower Motor
• Inspect Wiring
• Inspect Burner
• Inspect Orfices For Blockage
• Carbon Monoxide Test
• Inspect Chimney
• Inspect Pressure Switch Lines
• Test Sequence Of Operation
• Inspect Heat Exchanger
• Check Ignitor
• Check/replace Filter
• Test Gas Shut Off
• Test Thermostat For Proper Operation
Brigette, O. Bloomingdale, IL
11-22-2021
Upon Arrival, Furnace Operations Are Good. Vent Motor Is Running High Amps, Running At 2.4 Amps. It's Rated For 1.4 Amps. The Blower Motor Is In Good Amp Range. The Furnace Interior, The Flame Sensor Was Really Dirty. Cleaned Up The Interior Of The Furnace, Motor Housing, Flame Sensor, Burner Assembly. Furnace Manufactured In May 1999. Offered Humidifier Maintenance & Customer Accepted.
Annual Furnace Preventative Maintenance:
Your Fall Preventative Maintenance Includes
- Clean Burner Assembly
- Clean Flame Sensor
- Inspect Heat Exchanger
- Check Igniter
- Test Safety Circuit
- Carbon Monoxide Test
- Check Sequence Operations
- Inspect Blower Motor And Cage
- Measure For Correct Airflow
- Tighten Electrical Connections
- Measure Volts/amps On Motors
- Change Filter
Humidifier Maintenance And Cleaning
Disassemble And Inspect Aprilaire Humidifier
-Clean Drain Assembly
-Clean Distribution Tray
-Clean Water Feed Tube
-Verify Water Flow, Clean Orifice
-Clean Or Replace Drain Tube As Needed
-Verify 24v Control Operation
-Replace Media Filter
Set Manual Controls @ 35% For Winter Opperaion.
Verify Automatic Control Set In WiFi Stat
Becky , D. Bloomingdale, IL
10-08-2021
Furnace Report
• Inducer Amps MNF/1.0 - Test/.90
• Clean Flame Sensor
• Inspect Blower Motor
• Inspect Wiring
• Inspect Burner
• Inspect Orfices For Blockage
• Carbon Monoxide Test
• Inspect Chimney
• Inspect Pressure Switch Lines
• Test Sequence Of Operation
• Inspect Heat Exchanger
• Check Ignitor (Recently Replaced)
• Check/replace Filter
• Test Gas Shut Off
• Test Thermostat For Proper Operation
Notes - Ignitor Has Been Replaced, Heat Exchanger Has Heavy Signs Of Rust
Mike , M. Bloomingdale, IL
12-06-2021