Are you looking for Air Conditioning maintenance in Barrington, IL ? Our AC and Air Conditioning service technicians have years of experience working on Central AC Systems like yours in Barrington, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your Cooling System back up and operating.
We offer Central Air Conditioner maintenance and maintenance agreements to keep your AC system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency Air Conditioner today.
We provide Air Conditioning Maintenance in Barrington, IL
We provide Air Conditioning Maintenance Agreements in Barrington, IL
Get Your Quote Today
A/C Report
Clean And Check Outdoor Condenser
High Pressure - 119
Low Pressure - 216
Ambient Temp - 60
Delta T Reading -19
Contactor Resistance Reading - No Issues
Low Voltage Wiring Check No Issues
Capacitor Reading 80/7.5@81.2/7.45
Clean Out Electrical Compartment Clean
Refrigeration Line Check - Low Side Insulation Well Insulated
Service Valve Cap No Issues
Amp Draw On Compressor -26.8@12.32
Amp Draw On Condenser Fan -1.05@.81
Lock Rotor Amps - 134@154 Recommended Hard Start Kit
Check Filter/Replaced Replaced Air Filter
Clean Drain No Issues
Test Blower Motor No Issues
Hard Start Device 3-5 Ton
The 5-2-1 Compressor Saver® Protects These Components By Significantly Reducing The Amount Of Time It Takes For Your Compressor To Start – In Some Cases Up To 50%. This Means Your Air Conditioner And Compressor Will Bear – The Stress, Strain And Heat Each And Every Time It Starts. Considering That Your Air Conditioner May Start Up More Than 6,000 Times In A Single Cooling Season, The Positive Impact That The 5-2-1 Compressor Saver Has On Your Air Conditioner Is Significant.. Ross, M. Barrington, IL 05-26-2022
Upon Arrival, I Met With Ken, Who Requested A Deep Cleaning For All Three Mini-split Units. I Removed And Cleaned All Blower Wheels, Cleaned The Coils, Added Drain Tablets, And Cleaned The Vanes. I Then Located The Condenser On The Roof And Checked The Pressures And Supply Temperature. All Units Are Now Working Properly. Ken, N. Barrington, IL 05-31-2024
A/C Report
Clean And Check Outdoor Condenser
High Pressure - 190
Low Pressure - 120
Ambient Temp - 60
Delta T Reading -19
Contactor Resistance Reading - No Issues
Low Voltage Wiring Check No Issues
Capacitor Reading 40/5@39.89/5.05
Clean Out Electrical Compartment Clean
Refrigeration Line Check - Low Side Insulation Well Insulated
Service Valve Cap No Issues
Amp Draw On Compressor -15.3@7.16
Amp Draw On Condenser Fan -1.1@.67
Lock Rotor Amps - 83@90.1 Recommended Hard Start Kit
Check Filter/Replace Replaced Air Filter
Clean Drain No Issues
Test Blower Motor No Issues Liz , M. Barrington , IL 05-26-2022
A/C Report
Clean And Check Outdoor Condenser
High Pressure - 150
Low Pressure - 66
Ambient Temp - 60
Delta T Reading -17
Contactor Resistance Reading - No Issues
Low Voltage Wiring Check No Issues
Capacitor Reading 30/3@22.5/3
Clean Out Electrical Compartment Clean
Refrigeration Line Check - Low Side Insulation Well Insulated
Service Valve Cap No Issues
Amp Draw On Compressor -11.5@8.89
Amp Draw On Condenser Fan -.90@.76
Lock Rotor Amps - 61@75.9
Check Filter/Replace Replaced Air Filter
Clean Drain No Issues
Test Blower Motor No Issues Ross, M. Barrington , IL 05-26-2022