Gas Furnace Maintenance
Are you looking for gas furnace maintenance in Aurora, IL ? Our heating and furnace service technicians have years of experience working on furnaces like yours in Aurora, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.
We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.
We provide gas furnace Maintenance Agreements in Aurora, IL
Upon Arrival, Furnace Operations Are Good, Motors Are Within Working Amp Rating. The Flame Sensor Was Dirty & Cleaned It Up. Post Clean Up, Furnace Operations Is Good
Annual Furnace Preventative Maintenance:
Your Fall Preventative Maintenance Includes
- Clean Burner Assembly
- Clean Flame Sensor
- Inspect Heat Exchanger
- Check Igniter
- Test Safety Circuit
- Carbon Monoxide Test
- Check Sequence Operations
- Inspect Blower Motor And Cage
- Measure For Correct Air Flow
- Tighten Electrical Connections
- Measure Volts/amps On Motors
- Change Filter
Wilda , K. Aurora, IL
10-01-2021
Furnace Report
• Inducer Amps MNF/.35 - Test/.27
• Clean Flame Sensor
• Inspect Blower Motor
• Inspect Wiring
• Inspect Burner
• Inspect Orfices For Blockage
• Carbon Monoxide Test
• Inspect Chimney
• Inspect Pressure Switch Lines
• Test Sequence Of Operation
• Inspect Heat Exchanger
• Check Ignitor
• Check/replace Filter
• Test Gas Shut Off
• Test Thermostat For Proper Operation
1.0
Brent , D. Aurora, IL
11-22-2021
Annual Furnace Preventative Maintenance:
Your Fall Preventative Maintenance Includes
- Clean Burner Assembly
- Clean Flame Sensor
- Inspect Heat Exchanger
- Check Igniter
- Test Safety Circuit
- Carbon Monoxide Test
- Check Sequence Operations
- Inspect Blower Motor And Cage
- Measure For Correct Air Flow
- Tighten Electrical Connections
- Measure Volts/amps On Motors
- Change Filter
Refrigeration Piping Insulation
Furnish And Install New Or Replacement Piping Insulation.
Brandon, Y. Aurora , IL
10-07-2021
Upon Arrival Pre Clean Up, Furnace Start-up Operations Are Good. Motors Amps Within Operation Rate. The Flame Sensor Was A Bit Dirty. Cleaned Up Motor Housing, The Interior Of The Furnace, Flame Sensor & Burner’s Assembly. The Current Filter Looks Brand New. Post-clean-up Start-up Operations Good. Furnace Manufactured In June 2018
Annual Furnace Preventative Maintenance:
Your Fall Preventative Maintenance Includes
- Clean Burner Assembly
- Clean Flame Sensor
- Inspect Heat Exchanger
- Check Igniter
- Test Safety Circuit
- Carbon Monoxide Test
- Check Sequence Operations
- Inspect Blower Motor And Cage
- Measure For Correct Air Flow
- Tighten Electrical Connections
- Measure Volts/amps On Motors
- Change Filter
Leonard, Z. Aurora , IL
10-21-2021
Upon Arrival, Verified Sequence Of Operation Through Thermostat. Tested Mechanical Components Of Furnace And Tested Output Of Unit Was Up To Manufacturing Specs. Changed Out Air Filter With One Provided By Homeowner During Visit. This Was Humidifiers First Season And Did Not Need To Maintained During Visit.
Brian & Sandy, K. Aurora, IL
04-10-2024
Furnace Report:
Furnace Report
• Inducer No Issues
• Clean Flame Sensor Cleaned Sensor
• Inspect Blower Motor No Issues
• Inspect Wiring No Issues
• Inspect Burner No Rust
• Inspect Orfices For Blockage Condensate Trap Clogged Cleared
• Carbon Monoxide Test 0ppm Found
• Inspect Chimney Na
• Inspect Pressure Switch Lines No Issues
• Test Sequence Of Operation No Issues
• Inspect Heat Exchanger No Issues
• Check Ignitor No Issues
• Check/replace Filter Filter Looks Clean
• Test Gas Shut Off No Issues
• Test Thermostat For Proper Operation No Issues
Jason , Y. Aurora , IL
12-22-2021
Furnace Report:
Furnace Report
• Inducer Amps MNF/ - Test/0.5A
• Clean Flame Sensor Cleaned Flame Sensor
• Blower Motor Capacitor MNF/ - Test/ N/A Relay
• Inspect Wiring All Wiring Is Good
• Inspect Burner Cleaned And Cleared Burners
• Inspect Orifices For Blockage No Blockages
• Carbon Monoxide Test No Issues
• Inspect Chimney Chimney/exhaust Is Venting Properly
• Inspect Pressure Switch Lines Cleared Pressure Switch Lines
• Test Sequence Of Operation Sequence Of Operations Is All Good And In Order
• Inspect Heat Exchanger No Cracks, Clean Flame
• Check Ignitor Ignitor Is All Good
• Check/replace The Filter Filter Is Clean
• Test Gas Shut Off No Issues
• Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Wilda , K. Aurora, IL
10-22-2022
Furnace Report:
Furnace Report
• Inducer No Issues
• Clean Flame Sensor Cleaned Sensor Dirty
• Inspect Blower Motor No Issues
• Inspect Wiring No Issues
• Inspect Burner No Rust
• Inspect Orfices For Blockage Cleared All Ports
• Carbon Monoxide Test 0ppm Found
• Inspect Chimney No Issues
• Inspect Pressure Switch Lines No Issues
• Test Sequence Of Operation No Issues
• Inspect Heat Exchanger No Issues
• Check Ignitor No Issues
• Check/replace Filter Replaced Air Filter
• Test Gas Shut Off No Issues
• Test Thermostat For Proper Operation No Issues
Patricia , B. Aurora, IL