Gas Furnace Maintenance
Are you looking for gas furnace maintenance in Addison, IL ? Our heating and furnace service technicians have years of experience working on furnaces like yours in Addison, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.
We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.
We provide gas furnace Maintenance Agreements in Addison, IL
Furnace Report
• Inducer Amps MNF/ - Test/2.0A
• Clean Flame Sensor Cleaned Flame Sensor
• Blower Motor Capacitor MNF/ - Test/ N/A Relay
• Inspect Wiring All Wiring Is Good
• Inspect Burner Cleaned And Cleared Burners
• Inspect Orifices For Blockage No Blockages
• Carbon Monoxide Test No Issues
• Inspect Chimney Chimney/exhaust Is Venting Properly
• Inspect Pressure Switch Lines Cleared Pressure Switch Lines
• Test Sequence Of Operation Sequence Of Operations Is Good And In Order
• Inspect Heat Exchanger No Issues. Clean Blue Flame No Cracks
• Check Ignitor Ignitor Is All Good
• Check/replace The Filter Recommend Replacing Filter
• Test Gas Shut Off No Issues
• Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Janet , B. Addison, IL
11-03-2022
Deep Coil Cleaning:
Deep Cleaning Of Evaporator Coil
Dissemble Coil Cabinet For Access To Evaporator
Clean All Accessible Coil Fins And End Loops
Coil/fin Brush All Aluminum/copper Coil Surfaces
Clean Drain Pan Of All Debris
Clear Condensate Lines Of Any Sludge
+ Does Not Include Cutting Of Refrigeration Piping For Access. An Additional Charge Will Be Added For Reclaiming, Evac, Startup.
Annual A/C Preventative Maintenance:
Clean And Check Outdoor Condenser
High Pressure - 200
Low Pressure - 70
Ambient Temp - 79
Delta T Reading -20
Contactor Resistance Reading -18
Low Voltage Wiring Check
Capacitor Reading 35/5
Clean Out Electrical Compartment
Refrigeration Line Check - Low Side Insulation
Service Valve Cap
Amp Draw On Compressor -11.3
Amp Draw On Condenser Fan -1.26
Check Filter/Replace
Clean Drain
Test Blower Motor
Service:
Boiler Report
• Draft Damper Operational
• Verify Circulation Motor Operational
• Inspect Wiring
• Inspect Burner
• Test Gas Valve
• Inspect Orfices For Blockage
• Carbon Monoxide Test
• Inspect Chimney
• Test Sequence Of Operation
• Inspect Heat Exchanger
• Test Spark Ignitor
• Test Gas Shut Off
• Test Thermostat For Proper Operation
Janet , B. Addison, IL
10-04-2021
Laurel , B. Addison , IL
02-06-2023
Annual Furnace Preventative Maintenance:
Your Fall Preventative Maintenance Includes
- Clean Burner Assembly
- Clean Flame Sensor
- Inspect Heat Exchanger
- Check Igniter
- Test Safety Circuit
- Carbon Monoxide Test
- Check Sequence Operations
- Inspect Blower Motor And Cage
- Measure For Correct Air Flow
- Tighten Electrical Connections
- Measure Volts/amps On Motors
- Change Filter
Jeff , W. Addison , IL
11-05-2021
• Inducer MNF 3.7/Test 2.2
• Clean Flame Sensor
• Inspect Blower Motor
• Inspect Wiring
• Inspect Burner
• Inspect Orfices For Blockage
• Carbon Monoxide Test
• Inspect Chimney
• Inspect Pressure Switch Lines
• Test Sequence Of Operation
• Inspect Heat Exchanger
• Check Ignitor
• Check/replace Filter
• Test Gas Shut Off
• Test Thermostat For Proper Operation
• Clean 3/4 Drain
Humidifier Maintenance And Cleaning
Disassemble And Inspect Aprilaire Humidifier
-Clean Drain Assembly
-Clean Distribution Tray
-Clean Water Feed Tube
-Verify Water Flow, Clean Orifice
-Clean Or Replace Drain Tube As Needed
-Verify 24v Control Operation
-Replace Media Filter
Annual A/C Preventative Maintenance:
Clean And Check Outdoor Condenser
High Pressure - 200
Low Pressure - 70
Ambient Temp - 70
Delta T Reading -20
Contactor Resistance Reading -
Low Voltage Wiring Check
Capacitor Reading 44.9/5
Clean Out Electrical Compartment
Refrigeration Line Check - Low Side Insulation
Service Valve Cap
Amp Draw On Compressor - 11.0
Amp Draw On Condenser Fan -1.2
Janet , B. Addison, IL
10-04-2021