Gas Furnace Maintenance

Gas Furnace Maintenance

Are you looking for gas furnace maintenance in Wheaton, IL ? Our heating and furnace service technicians have years of experience working on furnaces like yours in Wheaton, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace Maintenance Agreements in Wheaton, IL

Get Your Quote Today

Humidifier Maintenance: Humidifier Maintenance And Cleaning Disassemble And Inspect Aprilaire Humidifier -Clean Drain Assembly -Clean Distribution Tray -Clean Water Feed Tube -Verify Water Flow, Clean Orifice -Clean Or Replace Drain Tube As Needed -Verify 24v Control Operation -Replace Media Filter Set Manual Controls @ 35% For Winter Opperaion. Verify Automatic Control Set In WiFi Stat
Shanon, E. Wheaton , IL
01-13-2023

Justin , R. Wheaton , IL
12-09-2022

William , B. Wheaton , IL
12-09-2022
Furnace Report • Inducer Amps MNF/2.35 - Test/ • Clean Flame Sensor- Yes • Blower Motor Capacitor MNF/5mfd - Test/4.9mfd • Inspect Wiring-yes • Inspect Burner-yes • Inspect Orifices For Blockage-yes • Carbon Monoxide Test-no • Inspect Chimney Yes • Inspect Pressure Switch Lines- Yes • Test Sequence Of Operation-yes • Inspect Heat Exchanger No • Check Ignitor Yes 49.9 Ohms • Check/replace The Filter- Yes • Test Gas Shut Off- Yes • Test Thermostat For Proper Operation- Yes Furnace Report • Inducer Amps MNF/1.0 - Test/1.03 • Clean Flame Sensor Yes • Blower Motor Capacitor MNF/5mfd - Test/4.7mfd • Inspect Wiring Yes • Inspect Burner Yes • Inspect Orifices For Blockage Yes • Carbon Monoxide Test No • Inspect Chimney Yes • Inspect Pressure Switch Lines Yes • Test Sequence Of Operation Yes • Inspect Heat Exchanger No • Check Ignitor Yes 82.57 Ohms • Check/replace The Filter Yes • Test Gas Shut Off Yes • Test Thermostat For Proper Operation Yes
Tom, L. Wheaton , IL
11-03-2022
For Boiler Maintenance We Clean Out The Strainer For The Fill Valve After That We Took Burners Apart And Cleaned Them With A Brush We Also Inspected The Expansion Tank And Check The Air Vents For Any Leaks Or Possibilities Of Leaks After That Checked The Circulating Pump To Ensure That's Its Working And After We Cycled The Unit In Heating To Ensure Both Water Supply And Return Are Hot Systems Is Running As Designed.
Joe, B. Wheaton , IL
11-03-2022
Furnace Report • Inducer Amps MNF/ - Test/0.5A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/ N/A Relay • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned And Cleared Burners • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney Is Venting Properly • Inspect Pressure Switch Lines Cleared Pressure Switch Lines • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger No Issues. Clean Flame • Check Ignitor Ignitor Is All Good • Check/replace The Filter Filter Is Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
David , E. Wheaton , IL
10-29-2022
Verify Heat Operational Test Thermostat Eviction Notice For Rodents Discovered Chewed Wires In Outdoor A/c Repaired Wires In Outdoor A/c
Percy , R. Wheaton , IL
10-29-2022
Furnace Report • Inducer Amps MNF/ - Test/0.8A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/ [email protected] • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned And Cleared Burners • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney Is Venting Properly • Inspect Pressure Switch Lines Cleared Pressure Switch Lines • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger No Issues. Clean Flame No Cracks • Check Ignitor Ignitor Is All Good • Check/replace The Filter Filter Is Clean • Test Gas Shut Off No Issue • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Wes, M. Wheaton , IL
10-29-2022
Furnace Report • Inducer Amps MNF/ - Test/0.5A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/N/A Relay • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned And Cleared Burners • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney Is Venting Properly • Inspect Pressure Switch Lines Cleared Pressure Switch Lines • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger Heat Exchanger Is Good No Issues. No Cracks Clean Flame • Check Ignitor Ignitor Is All Good • Check/replace The Filter Replaced Filter • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Jarrett , H. Wheaton , IL
10-28-2022
Furnace Report • Inducer Amps MNF/1.2 - Test/.7 • Clean Flame Sensor Yes • Blower Motor Capacitor MNF/ 5mfd- Test/4.9 • Inspect Wiring Yes • Inspect Burner Yes • Inspect Orifices For Blockage Yes • Carbon Monoxide Test Yes • Inspect Chimney Leaking • Inspect Pressure Switch Lines Yes • Test Sequence Of Operation Yes • Inspect Heat Exchanger Yes • Check Ignitor 50.2 Ohms • Check/replace The Filter Clean Did Not Replaced • Test Gas Shut Off Yes • Test Thermostat For Proper Operation Yes
Joan , C. Wheaton , IL
10-28-2022
Furnace Report • Inducer Amps MNF/ - Test/ 2.7A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/ N/A Relay • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned And Cleared Burners • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney/exhaust Is Venting Properly • Inspect Pressure Switch Lines Cleared And Cleaned Pressure Switch Lines • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger No Issues • Check Ignitor It Is Good • Check/replace The Filter Filter Is Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
HE, S. Wheaton , IL
10-22-2022
Furnace Report: Furnace Report • Inducer Amps MNF/ - Test/ 0.3A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/ N/A Relay • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned And Cleared Burners • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney/exhaust Is Venting Properly • Inspect Pressure Switch Lines Cleared Lines • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger No Issues. No Cracks Clean Flame • Check Ignitor Ignitor Is All Good • Check/replace The Filter Replaced Filter • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Darren , C. Wheaton , IL
10-22-2022
• Inducer Amps MNF/ - Test/0.5A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/ [email protected] • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned Burners, They Are Free Of Obstruction • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney Is Venting Properly • Inspect Pressure Switch Lines Pressure Switch Lines Are Free Of Obstruction • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger Heat Exchanger Has No Cracks And Throws A Clean Flame • Check Ignitor Ignitor Has Good Continuity • Check/replace The Filter Filter Is Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues.
Mike , K. Wheaton, IL
10-15-2022
Furnace Report • Inducer Amps MNF/ - Test/1.2A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/ [email protected] • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned Burners, They Are Free Of Obstruction • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney Is Venting Properly • Inspect Pressure Switch Lines Pressure Switch Lines Are Feee Of Obstructions • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger Heat Exchanger Has No Cracks, Clean Flame • Check Ignitor Ignitor Has Good Continuity • Check/replace The Filter Filter Is Clean • Test Gas Shut Off • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Tom , W. Wheaton , IL
10-15-2022
Furnace Report: Furnace Report • Inducer Amps MNF/ - Test/ 0.5A • Clean Flame Sensor Cleaned Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/ N/A Relay • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned Burners. No Obstructions • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney Is Venting Properly • Inspect Pressure Switch Lines Pressure Switch Lines Are Free Of Obstruction • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger Heat Exchanger Is Good No Cracks Very Clean Flame • Check Ignitor Ignitor Has Good Continuity • Check/replace The Filter Replaced Aprilaire Filter #213 • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Cathie , W. Wheaton , IL
10-15-2022
Furnace Report: Furnace Report • Inducer Amps MNF/ - Test/ 1.1A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/[email protected] • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned Burners They Are Free Of Obstruction • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney Is Venting Properly • Inspect Pressure Switch Lines No Blockages They Are Free Of Obstruction • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger No Issues, No Cracks Very Clean Flame • Check Ignitor Ignitor Has Good Continuity • Check/replace The Filter Filter Is Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Fred , K. Wheaton , IL
10-15-2022
Furnace Report: Furnace Report • Inducer Amps MNF/ - Test/ 0.3A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/ N/A Relay • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned Burners, They Are Free Of Obstruction • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney Is Venting Properly • Inspect Pressure Switch Lines Pressure Switch Lines Are Free Of Obstruction • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger Heat Exchanger Is Good, No Cracks Very Clean Flame • Check Ignitor Ignitor Has Good Continuity • Check/replace The Filter Filter Is Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Neil , B. wheaton, IL
10-15-2022
Furnace Report: Furnace Report • Inducer Amps MNF/1.2 - Test/.89 • Clean Flame Sensor Cleaned Sensor • Blower Motor Capacitor MNF/5 - Test/4.9 • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orifices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation. No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues 51.4 Ohms .47 Amps • Check/replace The Filter Air Filter Looks Good • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues A/C Report Clean And Check Outdoor Condenser High Pressure - 220 Low Pressure - 105 Ambient Temp - 68 Delta T Reading -18 Contactor Resistance Reading - No Issues Low Voltage Wiring Check No Issues Capacitor Reading 35/5@35/4.8 Clean Out Electrical Compartment Cleaned Spider Webs Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap In Place Amp Draw On Compressor [email protected] Amp Draw On Condenser Fan [email protected] Lock Rotor Amps - [email protected] Recommended Hard Start Kit Check Filter/Replace Air Filter Looks Good Clean Drain No Leaks Test Blower Motor No Issues
Diane, R. Wheaton, IL
09-29-2022
Furnace Report • Inducer Amps MNF/ - Test/ 0.6A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/ N/A Relay • Inspect Wiring Wiring Is All Good No Issues • Inspect Burner Burners Are Good No Blockages • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney Is Venting Correctly No Issues • Inspect Pressure Switch Lines Pressure Switch Lines Are Free Of Blockages • Test Sequence Of Operation Sequence Of Operations Is Good • Inspect Heat Exchanger Heat Exchanger Is Good No Issues • Check Ignitor Ignitor Is Good • Check/replace The Filter Replaced Filter • Test Gas Shut Off Gas Shut Off Works No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Steven , W. Wheaton , IL
09-23-2022
T Furnace Report: Furnace Report Furnace 1st Floor • Inducer Amps MNF/ - Test/0.6A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/ N/A Relay • Inspect Wiring All Wiring Is Good • Inspect Burner Burners Are Clean And Free Of Obstruction • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney Is Venting Properly • Inspect Pressure Switch Lines Pressure Switch Lines Are Clean And Free Of Obstruction • Test Sequence Of Operation Sequence Of Operations Is Correct And In Order • Inspect Heat Exchanger Heat Exchanger Is Good. Clean Flame And No Backfire • Check Ignitor Ignitor Is Good No Issues • Check/replace The Filter Recommend Replacing Filter • Test Gas Shut Off Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues Furnace Report: Furnace Report Furnace 2nd Floor • Inducer Amps MNF/ - Test/0.6A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/ N/A Relay • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned Burners And They Are Free Of Obstruction • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney Is Venting Correctly • Inspect Pressure Switch Lines Pressure Switch Lines Are Free Of Obstruction • Test Sequence Of Operation Sequence Of Operations Are All Good • Inspect Heat Exchanger Heat Exchanger Is Good. Clean Flame And No Backfire • Check Ignitor No Issues • Check/replace The Filter Recommend Replacing Filter • Test Gas Shut Off No Issue • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Robert, M. Wheaton , IL
09-23-2022
Furnace Report: Furnace Report • Inducer Amps MNF/ 1.4- Test/1.3 • Clean Flame Sensor Cleaned Sensor Dirty • Blower Motor Capacitor MNF/5 - Test/4.8 • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orifices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace The Filter Air Filter Looks Good • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Spencer , J. Wheaton , IL
03-03-2022
Furnace Report: Furnace Report • Inducer Amps MNF/ .30- Test/.25 • Clean Flame Sensor Cleaned Sensor Dirty • Blower Motor Capacitor MNF/ - Test/NA • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orifices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace The Filter Air Filter Looks Good • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues Humidifier Maintenance: Humidifier Maintenance And Cleaning Disassemble And Inspect Aprilaire Humidifier -Clean Drain Assembly -Clean Distribution Tray -Clean Water Feed Tube -Verify Water Flow, Clean Orifice -Clean Or Replace Drain Tube As Needed -Verify 24v Control Operation -Replace Media Filter Set Manual Controls @ 35% For Winter Opperaion. Verify Automatic Control Set In WiFi Stat
Georgia , B. Wheaton , IL
03-03-2022
Furnace Report: Furnace Report • Inducer Amps MNF/ 1.45- Test/1.3 • Clean Flame Sensor Cleaned Sensor Dirty • Blower Motor Capacitor MNF/ 5- Test/4.8 • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orifices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace The Filter Air Filter Looks Good • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Sandy , J. Wheaton , IL
03-03-2022
Furnace Report: Furnace Report • Inducer Amps MNF/ 1.93- Test/1.79 • Clean Flame Sensor Cleaned Sensor Dirty • Blower Motor Capacitor MNF/ 5- Test/4.8 • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orifices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace The Filter Air Filter Is Good • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Patricia , M. Wheaton, IL
02-24-2022
Furnace Report: Furnace Report • Inducer No Issues • Clean Flame Sensor Cleaned Sensor Dirty • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orfices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Needs To Be Replaced • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Aaron, T. Wheaton , IL
02-01-2022
Furnace Report: Furnace Report 2nd Floor • Inducer No Issues • Clean Flame Sensor Cleaned Sensor Dirty • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Issues • Inspect Orfices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Replaced Air Filter • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues Furnace Report: Furnace Report 1st Floor • Inducer No Issues • Clean Flame Sensor Cleaned Sensor Dirty • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Issues • Inspect Orfices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Replaced Air Filter • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Tracey, C. Wheaton, IL
02-01-2022
Furnace Report: Furnace Report • Inducer Motor Kinda Noisy Making Loud Pitch Noise • Clean Flame Sensor Cleaned Sensor Dirty • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Issues • Inspect Orfices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Air Filter Looks Good • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
John, H. Wheaton, IL
02-01-2022
Furnace Report: Furnace Report Attic • Inducer No Issues • Clean Flame Sensor Cleaned Sensor Dirty • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orfices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Replaced Air Filter AA410 • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Shanon , E. Wheaton , IL
01-27-2022
Furnace Report: Furnace Report M/N - S/N - • Inducer • Clean Flame Sensor • Inspect Blower Motor • Inspect Wiring • Inspect Burner • Inspect Orfices For Blockage • Carbon Monoxide Test • Inspect Chimney • Inspect Pressure Switch Lines • Test Sequence Of Operation • Inspect Heat Exchanger • Check Ignitor • Check/replace Filter • Test Gas Shut Off • Test Thermostat For Proper Operation
Wes , M. Wheaton, IL
01-20-2022
Furnace Report: Furnace Report • Inducer No Issues • Clean Flame Sensor Cleaned Sensor Dirty • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orfices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Air Filter Looks Good • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Karen, S. Wheaton, IL
01-18-2022
Furnace Report: Furnace Report • Inducer No Issues • Clean Flame Sensor Cleaned Sensor Dirty • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orfices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney NA • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Air Filter Is Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Mike , K. Wheaton, IL
12-20-2021
Furnace Report: Furnace Report • Inducer [email protected] • Clean Flame Sensor Cleaned Sensor • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orfices For Blockage No Issues • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Air Filter Looks Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Mina & Carlos, R. Wheaton, IL
12-20-2021
Furnace Report: Furnace Report • Inducer NA • Clean Flame Sensor NA • Inspect Blower Motor NA • Inspect Wiring No Issues • Inspect Burner Cleaned Burners No Issues • Inspect Orfices For Blockage No Issues • Carbon Monoxide Test • Inspect Chimney No Issues • Inspect Pressure Switch Lines NA • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor NA • Check/replace Filter NA • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Joe, B. Wheaton, IL
12-20-2021
Furnace Report: Furnace Report • Inducer No Issues • Clean Flame Sensor Cleaned Sensor • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Rust Or Issues • Inspect Orfices For Blockage No Issues • Carbon Monoxide Test 0 Ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor NA • Check/replace Filter FILTER Is Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
William, B. Wheaton, IL
12-14-2021
Furnace Report: • Inducer Mmf/.35 @ .14 • Clean Flame Sensor Cleaned • Inspect Blower Motor No Issues • Inspect Wiring Everything Looks Good • Inspect Burner No Issues • Inspect Orfices For Blockage Cleared All Ports • Carbon Monoxide Test • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor Checked Amps And Ohms • Check/replace Filter Is Clean • Test Gas Shut Off Is Good • Test Thermostat For Proper Operation No Issues
Bill, N. Wheaton, IL
12-09-2021
Furnace Report: • Inducer Mmf .65 @ .25 • Clean Flame Sensor • Inspect Blower Motor Cleaned • Inspect Wiring Electrical Looks Good • Inspect Burner No Rust Or Bouncing Around • Inspect Orfices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney NA • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Faults • Inspect Heat Exchanger Looks Good • Check Ignitor Tested Ohms And Amps Good • Check/replace Filter Air Filter Was Just Replaced • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Cheryl , P. Wheaton, IL
12-09-2021
Furnace Report: Furnace Report • Inducer ( Needs To Be Replaced) • Clean Flame Sensor • Inspect Blower Motor • Inspect Wiring • Inspect Burner • Inspect Orfices For Blockage • Carbon Monoxide Test • Inspect Chimney • Inspect Pressure Switch Lines • Test Sequence Of Operation • Inspect Heat Exchanger • Check Ignitor • Check/replace Filter • Test Gas Shut Off • Test Thermostat For Proper Operation Humidifier Maintenance And Cleaning Disassemble And Inspect Aprilaire Humidifier -Clean Drain Assembly -Clean Distribution Tray -Clean Water Feed Tube -Verify Water Flow, Clean Orifice -Clean Or Replace Drain Tube As Needed -Verify 24v Control Operation -Replace Media Filter
Yannick , K. Wheaton, IL
12-06-2021
Furnace Report • Inducer Amps MNF.86 - Test/.76 • Clean Flame Sensor • Inspect Blower Motor • Inspect Wiring • Inspect Burner • Inspect Orfices For Blockage • Carbon Monoxide Test • Inspect Chimney • Inspect Pressure Switch Lines • Test Sequence Of Operation • Inspect Heat Exchanger • Check Ignitor • Check/replace Filter • Test Gas Shut Off • Test Thermostat For Proper Operation
Sarah , P. Wheaton , IL
11-23-2021
Furnace Report • Inducer Amps MNF/1.45 - Test/.65 • Clean Flame Sensor • Inspect Blower Motor • Inspect Wiring • Inspect Burner • Inspect Orfices For Blockage • Carbon Monoxide Test • Inspect Chimney • Inspect Pressure Switch Lines • Test Sequence Of Operation • Inspect Heat Exchanger • Check Ignitor • Check/replace Filter • Test Gas Shut Off • Test Thermostat For Proper Operation
Scott , D. Wheaton , IL
11-23-2021
Furnace Report: Furnace Report • Inducer Amps MNF/1.2 - .9 • Clean Flame Sensor • Inspect Blower Motor • Inspect Wiring • Inspect Burner • Inspect Orfices For Blockage • Carbon Monoxide Test • Inspect Chimney • Inspect Pressure Switch Lines • Test Sequence Of Operation • Inspect Heat Exchanger • Check Ignitor • Check/replace Filter • Test Gas Shut Off • Test Thermostat For Proper Operation
Diane, R. Wheaton, IL
11-12-2021
Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Joshua , L. Wheaton , IL
11-05-2021
Furnace Report: Furnace Report 1st Floor • Inducer Amps MNF/.65 - Test/.58 • Clean Flame Sensor • Inspect Blower Motor • Inspect Wiring • Inspect Burner • Inspect Orfices For Blockage • Carbon Monoxide Test • Inspect Chimney • Inspect Pressure Switch Lines • Test Sequence Of Operation • Inspect Heat Exchanger • Check Ignitor • Check/replace Filter • Test Gas Shut Off • Test Thermostat For Proper Operation • Clean Condensenseate Trap Furnace Report 2nd Floor • Inducer Amps MNF/.65 - Test/.28 • Clean Flame Sensor • Inspect Blower Motor • Inspect Wiring • Inspect Burner • Inspect Orfices For Blockage • Carbon Monoxide Test • Inspect Chimney • Inspect Pressure Switch Lines • Test Sequence Of Operation • Inspect Heat Exchanger • Check Ignitor • Check/replace Filter • Test Gas Shut Off • Test Thermostat For Proper Operation • Clean Condensenseate Trap
Erika , W. Wheaton, IL
11-05-2021
Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Grace , V. Wheaton, IL
11-03-2021
1st-floor Furnace - Pre-clean-up Start-up Operations Are Good. Vent Motor Bearings Are Going Bad, Loud Noise Coming From The Vent Motor, Operating Amps Are Running A Bit High, The Interior Of Furnace Pretty Rusted. Cleaned Up Motors Housing, Flame Sensor, Burner Assembly, The Interior Of The Furnace. Post-clean-up Start-up Operations Are Good But The Vent Motor Is Still Operating In High Amps. Furnace Manufactured In October 1994. 2nd-floor Furnace- Pre-clean-up Start-up Operations Are Good. The Interior Of The Furnace Was A Bit Dirty. Cleaned Up The Interior Of The Furnace, Flame Sensor, Burner Assembly & Motors Housing. Post-clean-up Start-up Operations Are Good. Motors Are Working Well Within Amp Rate. Air Filters Look Good In Both Furnaces Humidifier Maintenance: Humidifier Maintenance And Cleaning Disassemble And Inspect Aprilaire Humidifier -Clean Drain Assembly -Clean Distribution Tray -Clean Water Feed Tube -Verify Water Flow, Clean Orifice -Clean Or Replace Drain Tube As Needed -Verify 24v Control Operation -Replace Media Filter Set Manual Controls @ 35% For Winter Opperaion. Verify Automatic Control Set In WiFi Stat
David , D. Wheaton, IL
11-02-2021
Upon Arrival Pre Clean Up Start Up Operations Are Good. Interior Of Furnace Was A Bit Dirty. Cleaned Up Interior Of Furnace, Flame Sensor, Burner Assembly & Motors Housing . Post Clean Up Start Up Operations Are Good . Motors Are Working Well Within Amp Rate .Humidifier Maintenance Also Provided & New Media Air Filter.
Jolynn, B. Wheaton, IL
10-29-2021
Upon Arrival Pre Clean Up Start Up Operations Are Good. Interior Of Furnace Was A Bit Dirty. Cleaned Up Interior Of Furnace, Flame Sensor, Burner Assembly & Motors Housing . Post Clean Up Start Up Operations Are Good . Motors Are Working Well Within Amp Rate . Current Filter Is Pretty Clean. Humidifier Maintenance Also Provided. Furnace Manufactured In August 2009
Alan, B. Wheaton, IL
10-29-2021
Upon Arrival Pre Clean Up Start Up Operations Are Good. Interior Of Furnace Was A Bit Dirty. Cleaned Up Interior Of Furnace, Flame Sensor, Burner Assembly & Motors Housing . Post Clean Up Start Up Operations Are Good . Motors Are Working Well Within Amp Rate . Current Filter Is Pretty Clean.
Tom, W. wheaton, IL
10-29-2021
Upon Arrival, Pre-clean-up Start-up Operations Are Good, Motors Are Within Operating Amp Range, The Interior Of The Furnace Is In Good Shape. Cleaned Up Motor Housing, Flame Sensor, The Interior Of The Furnace, Burner Assembly. Post-clean-up Start-up Operations Good. Manufactured In April 2014. Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
John, D. Wheaton, IL
10-22-2021
Upon Arrival Pre Clean Up, Furnace Start-up Operations Are Good. Motors Amps Within Operation Rate. The Flame Sensor Was A Bit Dirty. Cleaned Up Motor Housing, The Interior Of The Furnace, Flame Sensor & Burner’s Assembly. The Current Filter Looks Brand New. Offered Humidifier Maintenance & The Homeowner Declined & Also Joe Would Like To Do The AC Maintenance In Spring 2022. Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Joe, S. Wheaton, IL
10-21-2021
Upon Arrival Pre Clean Up, Furnace Start-up Operations Are Good. Motors Amps Within Operation Rate. The Flame Sensor Was A Bit Dirty. Cleaned Up Motor Housing, The Interior Of The Furnace, Flame Sensor & Burner’s Assembly. The Current Filter Is Still Good, Recommended To Change It In About 3 Weeks. Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Judy , V. Wheaton , IL
10-20-2021
*2 Furnaces* Upon Arrival, Pre-clean-up Start-up Operations Are Good. Motors Are Working Well Within Amp Rate. The Flame Sensor Was Pretty Dirty In Both Furnaces. The Switches Are Good. Cleaned Up Flame Sensor, Motors Housing, Burner Assembly, Interior Of Furnaces. Both Air Filters Are In Ok Condition. Offered Humidifier Maintenance & The Homeowner Declined. Both Furnaces Were Manufactured In April 2013. Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Larissa, B. Wheaton , IL
10-15-2021
Pre Cleans Up, Furnace Start-up & Operations Are Good. Motors Are In Good Amp Working Rate. The Flame Sensor Was A Bit Dirty. Cleaned Up Motor Housing, The Interior Of The Furnace, Burner Assembly, Flame Sensor, Humidifier. Offered Humidifier Maintenance & Homeowner Accepted. Customers Will Change Out The Filter When The New One Arrives. Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter Humidifier Maintenance And Cleaning Disassemble And Inspect Aprilaire Humidifier -Clean Drain Assembly -Clean Distribution Tray -Clean Water Feed Tube -Verify Water Flow, Clean Orifice -Clean Or Replace Drain Tube As Needed -Verify 24v Control Operation -Replace Media Filter Set Manual Controls @ 35% For Winter Opperaion. Verify Automatic Control Set In WiFi Stat
Cathie , W. Wheaton , IL
10-11-2021
Upon Arrival Pre Clean Up Startup Was Good. Furnace Motors In Good Amp Working Rate. Cleaned Up Motors Housing, Burner Assembly, Flame Sensor, The Interior Of The Furnace. The Current Filter Is Still Good. Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Darren, C. Wheaton, IL
10-11-2021
Upon Arrival Customer Explained Unit Was Freezing Up. I Turned The Unit On To Verify Blower Operation, Discovered Blower On First And Second Failed. Recommend Replacement Of Both Blower Motor Recommend Replacement Of Filters To Prevent Future Failure 20x25x4 Box Filter Upon Arrival Customer Explained Unit Was Freezing Up. I Turned The Unit On To Verify Blower Operation, Discovered Blower On First And Second Failed. Recommend Replacement Of Both Blower Motor Recommend Replacement Of Filters To Prevent Future Failure 20x25x4 Box Filter Upon Arrival Customer Explained Unit Was Freezing Up. I Turned The Unit On To Verify Blower Operation, Discovered Blower On First And Second Failed. Recommend Replacement Of Both Blower Motor Removal Of Existing Motor And Install New Permanent Split Capacitor Rescue Motor.
Drew, T. Wheaton, IL
10-07-2021
Vent Working Working In Great Amp Range And So Is The Blower Motor. Furnace Is Kept Well Clean. Would Recommend Replacing Part Of The Vent Pipe Due To Rust & Hole In It Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Andrea , L. Wheaton, IL
10-07-2021
Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter Humidifier Maintenance And Cleaning Disassemble And Inspect Aprilaire Humidifier -Clean Drain Assembly -Clean Distribution Tray -Clean Water Feed Tube -Verify Water Flow, Clean Orifice -Clean Or Replace Drain Tube As Needed -Verify 24v Control Operation -Replace Media Filter Set Manual Controls @ 35% For Winter Opperaion. Verify Automatic Control Set In WiFi Stat
Natalie, V. Wheaton, IL
10-07-2021
Furnace Report: Furnace Report • Inducer MNF.40 / Test .34 • Clean Flame Sensor • Inspect Blower Motor • Inspect Wiring • Inspect Burner • Inspect Orfices For Blockage • Carbon Monoxide Test • Inspect Chimney • Inspect Pressure Switch Lines • Test Sequence Of Operation • Inspect Heat Exchanger • Check Ignitor • Check/replace Filter • Test Gas Shut Off • Test Thermostat For Proper Operation Water Heater Cleaning Connect Drain Line Open Water Valve Flush Sediment Shut Water Valve
Jin , B. Wheaton, IL
09-30-2021
Furnace Operations Are Good, Motors In Proper Working Amp Range. Furnace Manufactured In NOV 2012. Filter Was Really Dirty, Put New Filter In Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Allie , W. Wheaton, IL
09-30-2021
Upon Arrival, Checked Sequence Of Operations & All Are Good. Motors Are Within Rated Amp Range. Interior, Flame Sensor & Burner Assembly Cleaned Up. Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Steven , W. Wheaton, IL
09-30-2021
Vent Working Working In Great Amp Range And So Is The Blower Motor. Furnace Is Kept Well Clean. Would Recommend Replacing Part Of The Vent Pipe Due To Rust & Hole In It FPM Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Andrea , L. Wheaton, IL
09-29-2021
EVAP DC Evaporator Coil Deep Cleaning: Clean Clogged Evaporator Coil. Open Plenum And Or Cased Coil To Access Coil And Clean With Coil Brushes And Or Coil Cleaner. Check Condensate Drain Line And Flush Or Blow Out Lines. Verify Coil Pan Is Clean And Properly Pitched. (Cutting Refrigeration Lines If Required Additional Cost) Service Service: Furnace Cleaning Remove Plenum Disassemble Blower Compartment Remove Blower Motor Disassemble Circuit Board Disassemble Heat Exchanger Compartment Vaccum All Compartments Reassemble All Compartments Verify Blower Operation Cycle Heat TRPCRG Residential Diagnosis Fee: Residential Service & Diagnosis Includes 1 Hour Of Standard Diagnosis On One HVAC System. Each Additional System Diagnosis Will Have An Additional Fee.
Rebecca , S. Wheaton , IL
09-29-2021
Furnace Motors All Working Well . Cleaned Up Motors & Flame Sensor
Joe , S. Wheaton , IL
09-21-2021
Upon Arrival, Called For Heat And Furnace Is Operating Good. Clean And Check On All Motors In Furnace. Furnace Seems To Have Taken Water Damage From Freezing AC Lines, Customer Stated One Our Techs Has Came Out To Their Home A Month Prior & Put Dye In Their System For Leak Check.
Julie, H. Wheaton, IL
09-20-2021
Both Furnaces Are In Great Working Condition, Both Were Really Dirty Inside. Cleaned Up Motors & Safety Sensor.
David , T. Wheaton , IL
09-20-2021
Both Furnaces Are In Great Working Condition, Both Were Really Dirty Inside. Cleaned Up Motors & Safety Sensor.
David , T. Wheaton , IL
09-20-2021
Preventative Maintenance.
Merrilee , R. Wheaton, IL
02-22-2021

Brian's Heatingstarstarstarstarstar4.6 / 5

5 stars
45
4 stars
0
3 stars
0
2 stars
1
1 stars
0

49 Total Reviews /files//brians-logo.png630-509-8310$847 Weyrauch St. , West Chicago IL