Are you looking for gas furnace maintenance in West Chicago, IL ? Our heating and furnace service technicians have years of experience working on furnaces like yours in West Chicago, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace Maintenance Agreements in West Chicago, IL

Get Your Quote Today

Upon Arrival, Verify Sequence Of Operations Through Thermostat. Tested Mechanical Components And Tested Output Of Unit And Everything Tested Between Manufacturing Specs. Recommended Humidifier Maintenance And Homeowner Approved. Changed Out Air Filter With One Provided By Homeowner.
Dave, V. West Chicago, IL
04-10-2024
Upon Arrival, Verified Sequence Of Operation Through Thermostat And Tested Mechanical Components Of Furnace And Everything Tested Between Manufacturing Specs. Inducer Motor Bearings Are Slightly Making Noise But Amping Between Range. Found Blower And Filter Extremely Dirty. Found Duct Work Very Dirty And Recommended Duct Cleaning And Then During Ac Cleaning We Do Blower Cleaning Then. Completed Humidifier Maintenance And Dryer Vent Cleaning During Visit.
Cathy, G. West Chicago, IL
04-10-2024
Furnace Report: Furnace Report • Inducer Amps MNF/ - Test/ 0.3A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/N/A Relay • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned And Cleared Burners • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney/exhaust Is Venting Properly • Inspect Pressure Switch Lines Cleared Pressure Switch Lines • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger No Issues. Very Clean Flame • Check Ignitor Ignitor Is All Good • Check/replace The Filter Replaced Filter 10-25-22 • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Steve , S. West Chicago , IL
10-29-2022
Furnace Report • Inducer Amps MNF/ - Test/0.3A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/N/A Relay • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned And Cleared Burners • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney/ Exhaust Is Venting Properly • Inspect Pressure Switch Lines Cleared Pressure Switch Lines • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger No Issues. Very Clean Blue Flame No Cracks • Check Ignitor Ignitor Is All Good • Check/replace The Filter Filter Is Clean/electronic • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Anke, K. West Chicago, IL
10-29-2022
Furnace Report • Inducer Amps MNF/ - Test/0.8A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/ [email protected] • Inspect Wiring ALL WIRING IS GOOD • Inspect Burner Cleaned And Cleared Burners • Inspect Orifices For Blockage No • Carbon Monoxide Test No Issues • Inspect Chimney Chimney Is Venting Properly • Inspect Pressure Switch Lines Cleared Pressure Switch Lines • Test Sequence Of Operation Sequence Off Operations Is Good And In Order • Inspect Heat Exchanger No Issues. No Cracks Clean Flame • Check Ignitor Ignitor Is All Good • Check/replace The Filter Filter Is Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Ronda , Y. West Chicago , IL
10-22-2022
Furnace Report • Inducer Amps MNF/ - Test/2.2A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/N/A Relay • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned And Cleared Burners • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney/exhaust Is Venting Properly • Inspect Pressure Switch Lines Cleared Pressure Switch Lines • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger Heat Exchanger Is Good No Cracks Clean Flame • Check Ignitor Ignitor Is All Good • Check/replace The Filter Filter Is Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Tom , S. West Chicago , IL
10-22-2022
Furnace Report • Inducer Amps MNF/ - Test/ 0.5A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/ N/A Relay • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned Burners They Are Free Of Obstruction • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney Is Venting Properly • Inspect Pressure Switch Lines Cleared Pressure Switch Lines, They Are Free Of Obstruction • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger Heat Exchanger Is Getting Rusty Inside But Working. • Check Ignitor Ignitor Has Good Continuity • Check/replace The Filter Filter Is Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues .
Tim , G. West Chicago , IL
10-15-2022
Furnace Report: Furnace Report • Inducer No Issues • Clean Flame Sensor Cleaned Sensor Dirty • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Issues • Inspect Orfices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Air Filter Looks Good • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues Humidifier Maintenance: Humidifier Maintenance And Cleaning Disassemble And Inspect Aprilaire Humidifier -Clean Drain Assembly -Clean Distribution Tray -Clean Water Feed Tube -Verify Water Flow, Clean Orifice -Clean Or Replace Drain Tube As Needed -Verify 24v Control Operation -Replace Media Filter Set Manual Controls @ 35% For Winter Opperaion. Verify Automatic Control Set In WiFi Stat
Ronda , Y. West Chicago , IL
01-27-2022
Furnace Report: Furnace Report • Inducer [email protected] • Clean Flame Sensor Cleaned Sensor • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orfices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Replaced Air Filter • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Bill, B. West Chicago, IL
01-14-2022
Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Francine, M. West Chicago, IL
12-20-2021
Furnace Report: Furnace Report • Inducer Mmf .30 @ .28 • Clean Flame Sensor Sensor Is Cleaned • Inspect Blower Motor Blower Motor Looks Good • Inspect Wiring No Issues • Inspect Burner No Issues Or Rust • Inspect Orfices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Filter Is Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Ken , S. West Chicago, IL
12-14-2021

Bernie , M. west chicago , IL
11-09-2021
*2 Furnaces * Upon Arrival Pre Clean Up Start-up Operations Were Good. Motors In Both Furnaces Work Well Within The Operation Amp Rate. Switches Are Good, Flame Sensor Dirty & Burner Assembly Dirty In Both Furnaces. Cleaned Up Motor Housing, Flame Sensor, Burner Assembly & Interior Of The Furnace. Also Offered Humidifier Maintenance And Homeowner Accepted. The Humidifier In Good Operation & Did A Check-up On Both Rent Halo Lights & They’re Both In Good Operation. Humidifier Maintenance And Cleaning Disassemble And Inspect Aprilaire Humidifier -Clean Drain Assembly -Clean Distribution Tray -Clean Water Feed Tube -Verify Water Flow, Clean Orifice -Clean Or Replace Drain Tube As Needed -Verify 24v Control Operation -Replace Media Filter Set Manual Controls @ 35% For Winter Opperaion. Verify Automatic Control Set In WiFi Stat Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Mark , B. West Chicago, IL
10-20-2021
Upon Arrival Pre-clean Start-up Operations Are Good. Motors Are Working Great, Well Within The Amp Operation Rate, The Flame Sensor Was Dirty. Cleaned Up The Interior Of Furnace, Motors Housing, Flame Sensor, Burner Assembly. Recommend Changing The Current Filter At The End Of The Month. Rent Halo Led Light Still In Good Operation. Offered Humidifier Maintenance & The Homeowner Declined. Post Clean Up Start-up Operations Are Good Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
J Mark, B. West Chicago, IL
10-13-2021
2nd-floor Furnace- Pre-clean-up Start-up Operations Are Good. The Interior Of The Furnace Has Rust, The Vent Motor Is Working A Bit On Amps, Blower Motor Amp Work Rate Is Good. Cleaned Up Motors Housing, The Interior Of The Furnace, Burner Assembly, Flame Sensor. Post-clean-up Start-up Operations Are Good. 1st-floor Furnace- Pre-clean-up Start-up Operations Are Good. Rusting Inside Furnace& Outside. Motors Are Working In A Good Operation Amp Range. Cleaned Up Motors Housing, The Interior Of The Furnace, Burner Assembly, Flame Sensor. Post-clean-up Start-up Operations Good. Both Furnaces Manufactured In July 2006, Current Filters Still Good, Recommend Change At The End Of The Month. I Checked The AC System @ Homeowner's Request, Having A Huge Amp Draw On The Condenser Closest To The Disconnect Wall. Amp Draw Is Way Too High For Operating Conditions. The Customer Would Like To Talk To Miguel About Replacement. Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Kristin , W. West Chicago , IL
10-11-2021
Furnace In The Kennel Closet - Was Pretty Dirty,operating Good. Amps On Motor Are In Rate Range. Cleaned Up Motor Housing, Burner Assembly,flame Sensor & Interior Of Furnace. Interior Of Furnace Is Rusting Out. Filter Changed Kennel Furnace On Ceiling - Operations Are Good. Motors Are In Rate Range Also Cleaned Up Motor Housing, Burner Assembly,flame Sensor & Interior Of Furnace. Filter Changed Payne Furnace - Flame Sensor Was Pretty Dirty , Motors Are Operating In Proper Amp Range. Cleaned Up Motor Housing, Burner Assembly,flame Sensor & Interior Of Furnace. Current Filter Still Good, Recommend Change In A Month. Basement Furnace- Operations Are Good. Motors Are Operating In Proper Amp Range. Cleaned Up Motor Housing, Burner Assembly,flame Sensor & Interior Of Furnace & Also Changed Filter.
Paw Print , G. West Chicago , IL
10-08-2021
Upon Arrival, Furnace Operations Are Good. Motors Are Working Within Amp Rated Range. Burner Assembly, Motors, The Interior Of The Furnace Were All Cleaned Up. The Humidifier Is In Good Working Order. Furnace Manufactured In July 2014. Comfort Sync A3 Is The Smart Thermostat I Explained About Today. Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Airflow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter Disassemble And Inspect Aprilaire Humidifier -Clean Drain Assembly -Clean Distribution Tray -Clean Water Feed Tube -Verify Water Flow, Clean Orifice -Clean Or Replace Drain Tube As Needed -Verify 24v Control Operation -Replace Media Filter Set Manual Controls @ 35% For Winter Opperaion. Verify Automatic Control Set In WiFi Stat
Alex, M. West Chicago, IL
10-01-2021
Upon Arrival, Furnace Operations Are Good, Blower Motor Is Working In The Proper Amp Range . Vent Motor Housing Starting To Rust & Running A Bit High On Amps (recommend Replacing). 20x20x1 Filter Size FPM Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Maria , D. West Chicago , IL
09-22-2021
Upon Arrival. Furnace Operations Are Good. Amp Motors Are In Working Rate But Vent Motor A Bit High . Furnace Clean & Check FPM Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Maria , D. West Chicago , IL
09-21-2021
Armstrong Furnace In Good Working Condition. Motors Work Well Under Their Amp Max Working Rate FPM Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Dana , W. West Chicago , IL
09-21-2021
Furnace Is Doing Good For Its Age, Motors Both Under Max Amp Rating . Good Blue Flame In The Burners
Tim , G. West Chicago , IL
09-20-2021
Wrong Size Filter Was Replace.
Francine, M. West Chicago, IL
09-15-2021
Annual Clean And Inspection Of Gas Furnace. Also Checked All Gas Connections On Furnace And Hot Water Tank For Any Gas Leaks As Customer Was Worried About Gas Smell.