If your gas furnace in Glen Ellyn, IL is not working it is likely your furnace needs repair or service. At times the fix is simple, other times it is not. Our heating and furnace service technicians have years of experience working on furnaces like yours in Glen Ellyn, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

Our furnace repair, furnace service or replacement pricing is very competitive. Our estimates are always firm with no hidden surprises. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace service in Glen Ellyn, IL

We provide gas furnace repair in Glen Ellyn, IL

Get Your Quote Today

Flame Sensor Replacement Remove And Replace Flame Sensor Dissemble Remove Clean And Reassemble As Needed Verify Operation Record Ohm Value Furnace Report • Inducer Amps MNF/ 1.5- Test/1.2 • Clean Flame Sensor Replaced Sensor • Blower Motor Capacitor MNF/5 - Test/4.7 • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orifices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace The Filter Air Filter Looks Good • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Brian , C. Glen Ellyn , IL
04-23-2022
Replaced High Limit Tested Furnace No Other Issues
Bryan , F. Glen Ellyn , IL
04-01-2022
Service Communicate With Tech Support Test Gas Pressure Lower Gas Pressure Test Co - 30ppm Test Exhaust Joints Discussed Warranty With Tech Support
Kelly, N. Glen Ellyn , IL
12-27-2021
Humidifier Maintenance: Humidifier Maintenance And Cleaning Disassemble And Inspect Aprilaire Humidifier -Clean Drain Assembly -Clean Distribution Tray -Clean Water Feed Tube -Verify Water Flow, Clean Orifice -Clean Or Replace Drain Tube As Needed -Verify 24v Control Operation -Replace Media Filter Set Manual Controls @ 35% For Winter Opperaion. Verify Automatic Control Set In WiFi Stat Furnace Report: Furnace Report • Inducer No Issues • Clean Flame Sensor Cleaned Sensor • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orfices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Air Filter Looks Good • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues Customer Mentioned That The Furnace Makes A Banging Noise When It Turns Off Told Her Is The Duct Work Expanding And Contracting
Cheryl , G. Glen Ellyn, IL
12-27-2021
Furnace Report: Furnace Report • Inducer Amps MNF/1.5 - Test/.90 • Clean Flame Sensor (clean) • Inspect Blower Motor • Inspect Wiring • Inspect Burner • Inspect Orfices For Blockage • Carbon Monoxide Test • Inspect Chimney • Inspect Pressure Switch Lines • Test Sequence Of Operation • Inspect Heat Exchanger • Check Ignitor • Check/replace Filter • Test Gas Shut Off • Test Thermostat For Proper Operation
Claudia , H. Glen Ellyn, IL
12-14-2021
Flame Sensor: Flame Sensor Replacement
Ron, T. Glen Ellyn, IL
11-05-2021
Service Unit Calling For Heat, Inducer Turns On And Pulls In Pressure Switch. I Verified Pressure Switches Are Pulling In By Doing Contuintity Test, I Cleaned Out Condesate Drain To Verify No Blockage. Tested All Pressure Switches Independently. Diagnosis - Faulty Circuit Board
Larry , S. Glen Ellyn , IL
11-03-2021
Upon Arrival, I Noticed The System Was Struggling With Cooling The House. The Customer Explained The Lack Of Airflow Coming Out The Vent. It Appears The System Is Low On Refrigerant Causing The Unit To Freeze Up As It Was Having A Hard Time Cooling. As The Age Of Both Units Is Are 23 Years Old I Recommend Replacing The Units To Prevent Future Failure
Elizabeth, M. Glen Ellyn , IL
09-23-2021
No Heat Upon Arrival - Did Electrical Diagnosis And Was Able To Restore Heat
Nancy, K. Glen Ellyn, IL
05-17-2019
"No Heat" On Arrival. Diagnosed Faulty Motherboard And Replaced With New OEM Part
Tracey, C. Glen Ellyn, IL
04-24-2019
Diagnosed Faulty Pilot Assembly
Judy, C. Glen Ellyn, IL
04-24-2019