If your gas furnace in Carol Stream, IL is not working it is likely your furnace needs repair or service. At times the fix is simple, other times it is not. Our heating and furnace service technicians have years of experience working on furnaces like yours in Carol Stream, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

Our furnace repair, furnace service or replacement pricing is very competitive. Our estimates are always firm with no hidden surprises. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace service in Carol Stream, IL

We provide gas furnace repair in Carol Stream, IL

Get Your Quote Today

Upon Arrival, Met With Business Owner And Mentioned How System Last Week Had Failed To Keep Up With Temp. When Arrived To System Thermostat The First Floor Thermostats Were Satisfied Temp. I Put The Temp Slightly Higher To Activate Heat And Tested Manufacturing Specs And Output Specifications. Temps Were Satisfied On Both Thermostat And Cycled Systems Multiple Times And Never Failed During Visit. Filters Are Clean And Temp Difference Was Between Specifications. Continued To Add Condensate Tablets To Condensate Lines As This Is A Common Issue Condensate Lines Build Up. Systems Are Working Appropriately At This Time. Did Not Charge For Tablets As This Should Have Been Added During PM Couple Weeks Ago, But Did Not Have On Truck.
Hancock International, H. Carol Stream, IL
04-04-2024
Upon Arrival Discovered Unit Operational But Gas Valve Malfunctioning. Got It To Fail After After The 5th Time. Offered Maintenance On The Furnace To Take The Burners Off And Clean Orfices. After Completion Of The Maintenance The Furnace Was Still Making A Blowing Noise From The Burners And The Gas Valve. The Gas Valve Needs To Be Replaced I Gave Him A Rough Estimate Of Replacing It So He Has An Idea.
Rob , P. Carol stream , IL
02-06-2023
Replaced Inducer Motor Tested Operation No Issues Let System Cycle No Faults.
John, H. Carol Stream , IL
04-01-2022
Upon Arrival Customer Mentioned That The Furnace Makes A Clicking Noise The Clicking Noise That She Is Hearing Is The Relays On Circuit Board Turning Each Component On Turned Off Furnace And Cycle System No Issues Found She Says It Reaches Satisfied Temp Every Time
Edelina , B. Carol Stream , IL
04-01-2022
Furnace Report: Furnace Report • Inducer Amps MNF/ 1.05- Test/.95 • Clean Flame Sensor Cleaned Sensor Dirty • Blower Motor Capacitor MNF/ - Test/ NA • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orifices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace The Filter Air Filter Looks Good • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Michael , P. Carol Stream , IL
03-25-2022
Upon Arrival Customer Mentioned That The Furnace Wouldn’t Ignite He Would Hear The Inducer Motor Ramp Up But Then Nothing When I Got Here He Said He Turned Off The Furnace A Couple Times And It Started Working I Found Error Code 228 Calibration Error Not Closing Pressure Switches I Suspect It’s Circuit Board Issue
Gary , E. Carol Stream, IL
01-08-2022
Urnace Report: Furnace Report • Inducer No Issues • Clean Flame Sensor Cleaned Sensor • Inspect Blower Motor Found Cap Rated @[email protected] • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orfices For Blockage No Issues • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Air Filter Looks Good • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Bill , S. Carol Stream, IL
01-06-2022
Customer Explained Inducer Turning In And Shutting Off Since Install. He Does Have Nest Thermostat Which Has Been Known To Drop Call For Heat On Armstrong Furnace. I Explained If Problem Persists We Could Install A Relay To Resolve The Issue
Deep, P. Carol Stream, IL
12-27-2021
Furnace Report: Furnace Report • Inducer No Issues • Clean Flame Sensor Cleaned Sensor • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orfices For Blockage No Issues • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Replaced Air Filter Really Dirty • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Cary, D. Carol Stream, IL
12-20-2021
Furnace Report: Furnace Report • Inducer Amps MNF/.43 - Test/.33 • Clean Flame Sensor • Inspect Blower Motor • Inspect Wiring • Inspect Burner • Inspect Orfices For Blockage • Carbon Monoxide Test • Inspect Chimney • Inspect Pressure Switch Lines • Test Sequence Of Operation • Inspect Heat Exchanger • Check Ignitor • Check/replace Filter • Test Gas Shut Off • Test Thermostat For Proper Operation
Lisette , C. Carol Stream, IL
12-06-2021
Upon Arrival Furnace Operations Were Good But The Flame Sensor Was Not Catching Proper Flame Detection & It Was Really Dirty. Also, The Burners Were Not Properly Aligned Causing The Flame Rollout Switch To Open. After Furnace Maintenance, Clean Up & Re-adjusting Position Of Flame Sensor & Burners .furnace Operations Are Good, Flame Sensor Is Getting Proper Micro Amps Based On Manufacturing. Cleaned Up Motor Housing, The Interior Of The Furnace, Flame Sensor, Burner Assembly. Post-clean-up Start-up Operations Good. Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Edelina , B. Carol Stream , IL
10-29-2021
"No Heat" On Arrival. Was Not Getting Ignition. Replaced Circuit Board And Igniter.
Cary, D. Carol Stream, IL
04-24-2019
Serviced Intermittent Blower Motor
Joe, A. Carol Stream, IL